Equations for Estimating the Predissected Diameter of the Descending Aorta From Computed Tomographic Images at the Onset of Aortic Dissection
Authors:
- Takashi YamauchiTYTakashi Yamauchi
- Osaka Cardiovascular Surgery Research Group (OSCAR)O(Osaka Cardiovascular Surgery Research Group (OSCAR)
Open Access
- 3 July 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 7 (13) , e009196
Abstract
Background: Estimation of the predissected descending aortic diameter is important for deciding on the size of a stent graft in cases of acute aortic dissection. However, no equations for estimating this diameter have been previously reported. Methods and Results: We developed and validated new equations by investigating computed tomography images that were scanned within 3 years before dissection and those that were scanned immediately after the onset of dissection. Among 1127 patients with acute aortic dissection (425 type A and 702 type B), 36 were matched for the study from October 2005 to March 2017 at 4 centers. New equations were developed in 17 patients and validated in 19 patients. We measured the predissected whole circumference length (CL) and postdissected whole CL , true lumen CL , the major diameter, and the minor diameter of the acutely dissected aorta, followed by calculation of (post‐true CL +post‐whole CL )/2 and (post–major diameter+post—minor diameter)/2. Six equations (linear function) and modified equations were derived from each of the above‐mentioned parameters. In the derivation sets, equations that used the parameter of (post‐true CL +post‐whole CL )/2 were strongly correlated with pre‐whole CL (Y=0.9433x+5.0147; R 2 =0.9001) and showed significantly less bias compared with the other 5 equations ( P <0.0001). In validation sets using this equation, the mean bias of the circumference length and diameter was 2.7±2.8 and 0.85±0.89 mm, respectively. A total of 99.2% of the calculated values were within 3 mm in diameter or less. Conclusions: Our newly developed equations can be used to calculate the predissected aortic diameter in cases of acute aortic dissection and might help to decide the size of the stent graft.Keywords
This publication has 15 references indexed in Scilit:
- Incidence and risk factors for retrograde type A dissection and stent graft-induced new entry after thoracic endovascular aortic repairJournal of Vascular Surgery, 2018
- Early outcomes of the conformable stent graft for acute complicated and uncomplicated type B aortic dissectionJournal of Vascular Surgery, 2017
- Early- and mid-term aortic remodelling after the frozen elephant trunk technique for retrograde type A acute aortic dissection using the new Japanese J Graft open stent graftInteractive CardioVascular and Thoracic Surgery, 2017
- Risk factors for stent graft-induced new entry after thoracic endovascular aortic repair for Stanford type B aortic dissectionJournal of Vascular Surgery, 2017
- Thoracic and cardiovascular surgery in Japan during 2014General Thoracic and Cardiovascular Surgery, 2016
- Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device designJournal of Vascular Surgery, 2016
- Choosing the correct treatment for acute aortic type B dissection.2015
- Factors predictive of distal stent graft-induced new entry after hybrid arch elephant trunk repair with stainless steel–based device in aortic dissectionThe Journal of Thoracic and Cardiovascular Surgery, 2013
- Total arch replacement with an open stent graft for acute type A aortic dissection: fate of the false lumenEuropean Journal of Cardio-Thoracic Surgery, 2009
- Midterm results of extensive primary repair of the thoracic aorta by means of total arch replacement with open stent graft placement for an acute type A aortic dissectionThe Journal of Thoracic and Cardiovascular Surgery, 2006