Asymptomatic Cerebral Emboli Following Carotid Artery Stenting: A Diffusion-Weighted MRI Study
Authors:
- Erkan KokluEKErkan Koklu
- Sakir ArslanSASakir Arslan
- Elif Sarionder GencerEGElif Sarionder Gencer
- Nermin BayarNBNermin Bayar
- Cagin Mustafa UreyenCUCagin Mustafa Ureyen
- Zehra ErkalZEZehra Erkal
- Ahmet GencAGAhmet Genc
- Ramazan GuvenRGRamazan Guven
- Oguz Kaan KayaOguz Kaan Kaya
- Muhammed Ridvan ErsoysalMEMuhammed Ridvan Ersoysal
Open Access
- 1 April 2022
- journal article
- research article
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 26 (4) , 298-304
Abstract
Background: Silent cranial embolism due to carotid artery stenting has been demonstrated to cause dementia, cognitive decline, and even ischemic stroke. The purpose of this study was to compare the periprocedural asymptomatic cranial embolism rates of different stent designs used for extracranial carotid stenosis with diffusion-weighted magnetic resonance imaging. Methods: A total of 507 consecutive patients who underwent carotid artery stenting at our center from December 2010 to June 2020 (mean age, 66.4 +/- 9.5) were analyzed retrospectively. The patients were divided into 3 groups as open-cell stent (334 patients), closed-cell stent (102 patients), and hybrid-cell stent (71 patients) groups. Diffusion-weighted magnetic resonance imaging was performed for the patients before and after carotid artery stenting and compared. The diffusion limitations of 3 stent groups on cranial diffusion-weighted magnetic resonance imaging were compared with one another. Results: Periprocedural asymptomatic same-side microembolism, which was the primary endpoint of our study, was detected in 58 (17.4%) patients in the open-cell stent group, 6 (5.9%) patients in the closed-cell group, and 8 (11.3%) patients in the hybrid cell group, and overall in 72 (14.2%) patients. On diffusion-weighted magnetic resonance imaging, periprocedural asymptomatic same-side cranial embolism was found to be statistically significantly higher in the open-cell group compared to the other two groups (P = .011). Conclusions: The result of this study showed us that the rate of same-side cranial embolism detected on cranial diffusion-weighted magnetic resonance imaging after carotid artery stenting performed with open-cell stent was higher than those of the carotid artery stenting procedure performed with closed-cell and hybrid-cell stents.Keywords
This publication has 28 references indexed in Scilit:
- Incidence of embolism associated with carotid artery stenting: open-cell versus closed-cell stentsJournal of Neurosurgery, 2013
- Risk Factors for Cerebral Embolization After Carotid Artery Stenting With Embolic ProtectionCirculation: Cardiovascular Interventions, 2013
- The PROFI Study (Prevention of Cerebral Embolization by Proximal Balloon Occlusion Compared to Filter Protection During Carotid Artery Stenting)JACC, 2012
- The Influence of Carotid Artery Catheterization Technique on the Incidence of Thromboembolism during Carotid Artery StentingAmerican Journal of Neuroradiology, 2010
- Stenting versus Endarterectomy for Treatment of Carotid-Artery StenosisNew England Journal of Medicine, 2010
- Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trialThe Lancet, 2010
- Filter-Protected versus Unprotected Carotid Artery Stenting: A Randomised TrialCerebrovascular Diseases, 2010
- New Brain Lesions After Carotid Stenting Versus Carotid EndarterectomyStroke, 2008
- Does Free Cell Area Influence the Outcome in Carotid Artery Stenting?European Journal of Vascular and Endovascular Surgery, 2007
- Early Outcome of Carotid Angioplasty and Stenting With and Without Cerebral Protection DevicesStroke, 2003