CLEAN beamforming for the enhanced detection of multiple infrasonic sources
- 8 January 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 221 (1) , 305-317
Abstract
SUMMARY: The detection and characterization of signals of interest in the presence of (in)coherent ambient noise is central to the analysis of infrasound array data. Microbaroms have an extended source region and a dynamical character. From the perspective of an infrasound array, these coherent noise sources appear as interfering signals that conventional beamform methods may not correctly resolve. This limits the ability of an infrasound array to dissect the incoming wavefield into individual components. In this paper, this problem will be addressed by proposing a high-resolution beamform technique in combination with the CLEAN algorithm. CLEAN iteratively selects the maximum of the f/k spectrum (i.e. following the Bartlett or the Capon method) and removes a percentage of the corresponding signal from the cross-spectral density matrix. In this procedure, the array response is deconvolved from the f/k spectral density function. The spectral peaks are retained in a ‘clean’ spectrum. A data-driven stopping criterion for CLEAN is proposed, which relies on the framework of Fisher statistics. This allows the construction of an automated algorithm that continuously extracts coherent energy until the point is reached that only incoherent noise is left in the data. CLEAN is tested on a synthetic data set and is applied to data from multiple International Monitoring System infrasound arrays. The results show that the proposed method allows for the identification of multiple microbarom source regions in the Northern Atlantic that would have remained unidentified if conventional methods had been applied.Keywords
Funding Information
- Human Frontier Science Program (RGY0072/2017)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (864.14.005)
This publication has 23 references indexed in Scilit:
- Effect of interarray elevation differences on infrasound beamformingGeophysical Journal International, 2012
- Slowness–azimuth corrections of teleseismic events for IMS primary arrays in ChinaJournal of Seismology, 2008
- CLEAN Based on Spatial Source CoherenceInternational Journal of Aeroacoustics, 2007
- ARRAY SEISMOLOGY: METHODS AND APPLICATIONSReviews of Geophysics, 2002
- Multiple emitter location and signal parameter estimationIEEE Transactions on Antennas and Propagation, 1986
- The acoustic telescopeJournal of Sound and Vibration, 1976
- Fast Frequency-Wavenumber Analysis and Fisher Signal Detection in Real-Time Infrasonic Array Data ProcessingGeophysical Journal of the Royal Astronomical Society, 1971
- On Detecting a Signal in N Stationarily Correlated Noise SeriesTechnometrics, 1971
- Multiple signal correlatorsGeophysics, 1957
- Smoothing Periodograms from Time-Series with Continuous SpectraNature, 1948