Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging
- 15 September 2013
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 115 (6) , 850-860
Abstract
Although some central aspects of pulmonary function (ventilation and perfusion) are known to be heterogeneous, the distribution of diffusive gas exchange remains poorly characterized. A solution is offered by hyperpolarized 129Xe magnetic resonance (MR) imaging, because this gas can be separately detected in the lung's air spaces and dissolved in its tissues. Early dissolved-phase 129Xe images exhibited intensity gradients that favored the dependent lung. To quantitatively corroborate this finding, we developed an interleaved, three-dimensional radial sequence to image the gaseous and dissolved 129Xe distributions in the same breath. These images were normalized and divided to calculate “129Xe gas-transfer” maps. We hypothesized that, for healthy volunteers, 129Xe gas-transfer maps would retain the previously observed posture-dependent gradients. This was tested in nine subjects: when the subjects were supine, 129Xe gas transfer exhibited a posterior-anterior gradient of −2.00 ± 0.74%/cm; when the subjects were prone, the gradient reversed to 1.94 ± 1.14%/cm ( P < 0.001). The 129Xe gas-transfer maps also exhibited significant heterogeneity, as measured by the coefficient of variation, that correlated with subject total lung capacity ( r = 0.77, P = 0.015). Gas-transfer intensity varied nonmonotonically with slice position and increased in slices proximal to the main pulmonary arteries. Despite substantial heterogeneity, the mean gas transfer for all subjects was 1.00 ± 0.01 while supine and 1.01 ± 0.01 while prone ( P = 0.25), indicating good “matching” between gas- and dissolved-phase distributions. This study demonstrates that single-breath gas- and dissolved-phase 129Xe MR imaging yields 129Xe gas-transfer maps that are sensitive to altered gas exchange caused by differences in lung inflation and posture.Keywords
This publication has 40 references indexed in Scilit:
- Chronic Obstructive Pulmonary Disease: Safety and Tolerability of Hyperpolarized129Xe MR Imaging in Healthy Volunteers and PatientsRadiology, 2012
- Diffusion‐weighted hyperpolarized 129Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary diseaseMagnetic Resonance in Medicine, 2010
- Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129Proceedings of the National Academy of Sciences, 2010
- Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in HumansPLOS ONE, 2010
- Supine and prone differences in regional lung density and pleural pressure gradients in the human lung with constant shapeJournal of Applied Physiology, 2009
- Pulmonary perfusion in the prone and supine postures in the normal human lungJournal of Applied Physiology, 2007
- Vertical gradients in regional lung density and perfusion in the supine human lung: the Slinky effectJournal of Applied Physiology, 2007
- Imaging alveolar–capillary gas transfer using hyperpolarized 129 Xe MRIProceedings of the National Academy of Sciences, 2006
- An overlap invariant entropy measure of 3D medical image alignmentPattern Recognition, 1999
- DlCO/Q̇ and diffusion limitation at rest and on exercise in patients with interstitial fibrosisRespiration Physiology, 1991