Interdependence of Modulated Dispersion and Tissue Structure in the Mechanism of Unidirectional Block
- 10 November 2000
- journal article
- other
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 87 (10) , 922-928
Abstract
—We previously showed that a premature stimulus can significantly alter vulnerability to arrhythmias by modulating spatial gradients of ventricular repolarization (ie, modulated dispersion). However, it is not clear if such changes in arrhythmia vulnerability can be attributed to the formation of an electrophysiological substrate for unidirectional block and what the potential role is of tissue structure in this process. Therefore, the main objective of the present study was to examine the concomitant effect repolarization gradients and tissue structure have on unidirectional block. Optical action potentials were recorded from 128 ventricular sites (1 cm 2 ) in 8 Langendorff-perfused guinea pig hearts. Propagation was confined to the epicardial surface using an endocardial cryoablation procedure, and a 12-mm barrier with a 1.5-mm isthmus was etched with a laser onto the epicardium. A premature stimulus (S2) was delivered over a range of S1S2 coupling intervals to modulate repolarization gradients in a predictable fashion. When a second premature stimulus (S3) was delivered from the center of the isthmus, the occurrence and orientation of unidirectional block were highly dependent on repolarization gradients created by the S2 beat. In this model, a local repolarization gradient of 3.2 ms/mm was required for unidirectional block at this isthmus. In addition, the formation of unidirectional block was critically dependent on the presence of the source-sink mismatch imposed by the isthmus. These results may explain how the interplay between spatial heterogeneities of repolarization and tissue structure form a substrate for unidirectional block and reentry.Keywords
This publication has 16 references indexed in Scilit:
- Nitric oxide activity in arterial and venous bypass graftsJACC, 1998
- Mechanism of Initiation of Atrial Flutter in Humans: Site of Unidirectional Block and Direction of Rotation 11All editorial decisions for this article, including selection of referees, were made by a Guest Editor. This policy applies to all articles with authors from the University of California San Francisco.JACC, 1997
- Role of wavefront curvature in propagation of cardiac impulseCardiovascular Research, 1997
- Conduction Barriers in Human Atrial Flutter:Journal of Cardiovascular Electrophysiology, 1996
- Lateral tunnel suture line variation reduces atrial flutter after the modified Fontan operationThe Annals of Thoracic Surgery, 1996
- Role of M cells in acquired long QT syndrome, U waves, and torsade de pointesJournal of Electrocardiology, 1995
- Regional variations in action potentials and transient outward current in myocytes isolated from rabbit left ventricle.The Journal of Physiology, 1991
- The functional role of structural complexities in the propagation of depolarization in the atrium of the dog. Cardiac conduction disturbances due to discontinuities of effective axial resistivity.Circulation Research, 1982
- Circus movement in rabbit atrial muscle as a mechanism of tachycardia. II. The role of nonuniform recovery of excitability in the occurrence of unidirectional block, as studied with multiple microelectrodes.Circulation Research, 1976
- On dynamic equilibrium in the heartThe Journal of Physiology, 1913