A Blink Restoration System With Contralateral EMG Triggered Stimulation and Real-Time Artifact Blanking
Authors:
- 23 April 2013
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 7 (2) , 140-148
Abstract
Patients suffering from facial paralysis are on the hazard of disfigurement and loss of vision due to loss of blink function. Functional-electrical stimulation (FES) is one possible way of restoring blink and other functions in these patients. A blink restoration system for uni-lateral facial paralyzed patients is described in this paper. The system achieves restoration of synchronized blink through processing the myoelectric signal of orbicularis oculi at the normal side in real-time as the trigger to stimulate the paralyzed eyelid. Design issues are discussed, including EMG processing, stimulating strategies and real-time artifact blanking. Two artifact removal approaches based on sample and hold and digital filtering technique are proposed and implemented. Finally, the whole system has been verified on rabbit models.Keywords
This publication has 37 references indexed in Scilit:
- Myoelectric signals of levator palpebrae superioris as a trigger for FES to restore the paralyzed eyelidMedical Hypotheses, 2012
- Electrical stimulation of excitable tissue: design of efficacious and safe protocolsJournal of Neuroscience Methods, 2005
- Stimulation artifact in surface EMG signal: effect of the stimulation waveform, detection system, and current amplitude using hybrid stimulation techniqueIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2003
- An enhanced feature extraction algorithm for EMG pattern classificationIEEE Transactions on Rehabilitation Engineering, 1996
- Stimulus artifact removal in EMG from muscles adjacent to stimulated musclesJournal of Neuroscience Methods, 1996
- A digital technique for stimulus artifact reductionElectroencephalography and Clinical Neurophysiology, 1990
- Suppression of stimulation artifacts from myoelectric-evoked potential recordingsIEEE Transactions on Biomedical Engineering, 1988
- Gold Weight and Wire Spring Implants as Alternatives to TarsorrhaphyJAMA Otolaryngology–Head & Neck Surgery, 1987
- Incidence, clinical features, and prognosis in Bell's palsy, Rochester, Minnesota, 1968–1982Annals of Neurology, 1986
- An electronic stimulus artifact suppressorElectroencephalography and Clinical Neurophysiology, 1971