Electron Beam Emission from a Diamond-Amplifier Cathode

Authors:
  • QWQiong Wu
    Qiong Wu
  • IBIlan Ben-Zvi
    Ilan Ben-Zvi
  • ABAndrew Burrill
    Andrew Burrill
  • JKJorg Kewisch
    Jorg Kewisch
  • TRTriveni Rao
    Triveni Rao
  • JSJohn Smedley
    John Smedley
  • EWErdong Wang
    Erdong Wang
  • EMErik M. Muller
    Erik M. Muller
  • RBRichard Busby
    Richard Busby
  • DDDimitre Dimitrov
    Dimitre Dimitrov

Abstract
The diamond amplifier (DA) is a new device for generating high-current, high-brightness electron beams. Our transmission-mode tests show that, with single-crystal, high-purity diamonds, the peak current density is greater than 400\,\,mA/mm2, while its average density can be more than 100\,\,mA/mm2. The gain of the primary electrons easily exceeds 200, and is independent of their density within the practical range of DA applications. We observed the electron emission. The maximum emission gain measured was 40, and the bunch charge was 50\,\,pC/0.5\,\,mm2. There was a 35% probability of the emission of an electron from the hydrogenated surface in our tests. We identified a mechanism of slow charging of the diamond due to thermal ionization of surface states that cancels the applied field within it. We also demonstrated that a hydrogenated diamond is extremely robust.

This publication has 12 references indexed in Scilit: