Separation of liquid mixtures by using polymer membranes. III. Grafted poly(vinyl alcohol) membranes in vacuum permeation and dialysis
Authors:
- 1 October 1981
- journal article
- research article
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 26 (10) , 3223-3243
Abstract
A series of poly(vinyl alcohol) membranes were modifed by radiation‐induced graft copolymerization with acrylic acid and methacrylic acid monomers. These grafted poly(vinyl alcohol) membranes were then tested for their separation and permeability characteristics in vacuum permeation and dialysis experiments. The permselectivity of the membranes toward methanol and water was studied on a vacuum permeation apparatus at 30, 40, and 50°C. The permeation process was found to be a temperature‐activated process. The logarithm of the permeation rate varied linearly with the reciprocal of the absolute temperature. The permeability of the grafted membranes was found to increase with the degree of grafting, with no appreciable selectivity toward water in binary mixtures. The acrylic acid‐grafted membranes generally showed greater improvement in permeability than the methacylic‐grafted membranes. The permeability of the grafted membranes toward methanol, sodium chloride, urea, creatinine, and uric acid was studied in a dialyzer. In all cases, the grafted membranes showed an improved permeability toward these solutes over the commercial poly(vinyl alcohol) membranes. The dialysis results were then compared with those obtained for dialysis‐grade cellophane membranes. For the case of sodium chloride, urea, and methanol, the permeability of the grafted membranes was comparable to that of cellophane. A comparison of commercial and grafted poly(vinyl alcohol) membranes in their permeability toward ionic solutes exhibited somewhat anomalous behavior in that the permeability of the commercial membranes was higher than that of the grafted membranes. This related to the ionic nature of the modified membrane. The permeability coefficients determined in the dialysis experiments were found to be directly related to the degree of hydration of the grafted membrane. This behavior was attributed to changes in the size and shape of voids within the membrane structure.Keywords
This publication has 17 references indexed in Scilit:
- Grafting acrylic acid monomer to poly‐(vinyl alcohol) and methyl cellulose by ceric ionJournal of Polymer Science Part A-1: Polymer Chemistry, 1969
- Relationship between reduction of ceric ion with poly(vinyl alcohol) and graft copolymerizationJournal of Polymer Science Part A-1: Polymer Chemistry, 1969
- Separation of liquid mixtures by using polymer membranes. I. Permeation of binary organic liquid mixtures through polyethyleneJournal of Applied Polymer Science, 1968
- Zum Mechanismus des Wassertransports durch semipermeable Membrane aus PolyvinylalkoholThe Science of Nature, 1965
- Crosslinking of Poly (vinylalcohol) by Treatment with Hydrochloric AcidKobunshi Kagaku, 1963
- Direct radiation grafting on to hydrophilic polymersThe International Journal of Applied Radiation and Isotopes, 1960
- Chemical Studies on the Effect of Radiation on Poly (vinylalcohol)Kobunshi Kagaku, 1960
- Sorption and diffusion in ethyl cellulose. Part II. Quantitative examination of settled isotherms and permeation ratesJournal of Polymer Science, 1957
- Effect of x‐rays and γ‐rays on synthetic polymers in aqueous solutionJournal of Polymer Science, 1957
- Diffusion of Vapors in FilmsJournal of the American Chemical Society, 1947