A Comparison of the Shear Bond Strength between a Luting Composite Resin and Both Machinable and Printable Ceramic–Glass Polymer Materials
Open Access
- 25 September 2024
- Vol. 17 (19) , 4697
Abstract
This study aims to compare the shear bond strength (SBS) and Weibull characteristics between a luting composite resin and both printable and two different machinable ceramic–glass polymer materials. A total of 36 substrates were prepared, with 12 in each group. Printable substrates (12 mm × 12 mm × 2 mm) were printed by using permanent crown resin (3D-PR). Machinable substrates were obtained from Cerasmart 270 (CS) and Vita Enamic (VE) blocks (2 mm in thickness). The bonding surfaces of substrates were polished and airborne abraded (50 µm Al2O3). A self-adhesive luting composite resin (RelyX U200, 3M ESPE, St. Paul, MN, USA, SLC) was applied on substrates with the help of a cylindrical (Ø3 × 3 mm) mold. The SBS test was conducted using a universal test machine. The SBSs of three materials were compared using a one-way analysis of variance (ANOVA) (α = 0.05). The Weibull modulus was calculated for each material. The Kruskal–Wallis and chi-square tests were carried out for the failure mode analysis. There was no significant difference between the SBSs of the three materials (p = 0.129). The Weibull modulus was 3.76 for the 3D-PR, 4.22 for the CS, and 6.52 for the VE group. Statistical analysis showed no significant difference between the failure modes of the groups (p = 0.986). Mixed-failure fractures were predominantly observed in all three groups. The results show that the SBS of the SLC to printable 3D-PR is comparable to that of CS and VE material. Failure modes of printable 3D-PR show similar results with two different machinable ceramic–glass polymers.Keywords
Funding Information
- Scientific Research Projects Coordination unit of Cukurova University (TSA-2021-14200)
This publication has 49 references indexed in Scilit:
- Bond strength between temporary 3D printable resin and conventional resin composite: influence of cleaning methods and air-abrasion parametersClinical Oral Investigations, 2022
- Effect of sandblasting and/or priming treatment on the shear bond strength of self-adhesive resin cement to CAD/CAM blocksOdontology, 2021
- Bonding to new CAD/CAM resin composites: influence of air abrasion and conditioning agents as pretreatment strategyClinical Oral Investigations, 2018
- Dental Cements for Luting and Bonding RestorationsDental Clinics of North America, 2017
- Adhesion to tooth structure: A critical review of “macro” test methodsDental Materials, 2010
- Direct comparison of the bond strength results of the different test methods: A critical literature reviewDental Materials, 2010
- Variables related to materials and preparing for bond strength testing irrespective of the test protocolDental Materials, 2010
- Relationship between bond-strength tests and clinical outcomesDental Materials, 2010
- A practical and systematic review of Weibull statistics for reporting strengths of dental materialsDental Materials, 2010
- Effect of thermocycling on bond strength of luting cements to zirconia ceramicDental Materials, 2006