Systematic investigation of the signal properties of polycrystalline HgI2detectors under mammographic, radiographic, fluoroscopic and radiotherapy irradiation conditions
Authors:
- Larry E AntonukLALarry E Antonuk
- Youcef El-MohriYEYoucef El-Mohri
- Larry HuLHLarry Hu
- Hong DuHDHong Du
- Amit SawantASAmit Sawant
- Yixin LiYLYixin Li
- Yi WangYWYi Wang
- Jin YamamotoJYJin Yamamoto
- Qihua ZhaoQZQihua Zhao
- 1 June 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (12) , 2907-2928
Abstract
The signal properties of polycrystalline mercuric iodide (HgI2) film detectors, under irradiation conditions relevant to mammographic, radiographic, fluoroscopic and radiotherapy x-ray imaging, are reported. Each film detector consists of an approximately 230 to approximately 460 microm thick layer of HgI2 (fabricated through physical vapour deposition or a screen-print process) and a thin barrier layer, sandwiched between a pair of opposing electrode plates. The high atomic number, high density and low effective ionization energy, W(EFF), of HgI2 make it an attractive candidate for significantly improving the performance of active matrix, flat-panel imagers (AMFPIs) for several x-ray imaging applications. The temporal behaviour of current from the film detectors in the presence and in the absence of radiation was used to examine dark current levels, the lag and reciprocity of the signal response, x-ray sensitivity and W(EFF). The results are discussed in the context of present AMFPI performance. This study provides performance data for a wide range of potential medical x-ray imaging applications from a single set of detectors and represents the first investigation of the signal properties of polycrystalline mercuric iodide for the radiotherapy application.Keywords
This publication has 47 references indexed in Scilit:
- Systematic development of input-quantum-limited fluoroscopic imagers based on active-matrix flat-panel technology2004
- a-Si:H TFT-Based Active Matrix Flat-Panel Imagers For Medical X-Ray Applications2004
- Multilayer Gafchromic film detectors for breast skin dose determinationin vivoPhysics in Medicine & Biology, 2002
- 40 x 30 cm flat-panel imager for angiography, R&F, and cone-beam CT applications2001
- Strategies to improve the signal and noise performance of active matrix, flat‐panel imagers for diagnostic x‐ray applicationsMedical Physics, 2000
- Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammographyMedical Physics, 1997
- An accurate method for computer‐generating tungsten anode x‐ray spectra from 30 to 140 kVMedical Physics, 1997
- Empirical investigation of the signal performance of a high‐resolution, indirect detection, active matrix flat‐panel imager (AMFPI) for fluoroscopic and radiographic operationMedical Physics, 1997
- Radiation response of amorphous silicon imaging arrays at diagnostic energiesIEEE Transactions on Nuclear Science, 1994
- Radiological imaging--2000 A.D.Radiology, 1981