Prediction of Gas Concentration Using Gated Recurrent Neural Networks
Authors:
- 1 August 2020
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 178-182
Abstract
Low-cost gas sensors allow for large-scale spatial monitoring of air quality in the environment. However they require calibration before deployment. Methods such as multivariate regression techniques have been applied towards sensor calibration. In this work, we propose instead, the use of deep learning methods, particularly, recurrent neural networks for predicting the gas concentrations based on the outputs of these sensors. This paper presents a first study of using Gated Recurrent Unit (GRU) neural network models for gas concentration prediction. The GRU networks achieve on average, a 44.69% and a 25.17% RMSE improvement in concentration prediction on a gas dataset when compared with Support Vector Regression (SVR) and Multilayer Perceptron (MLP) models respectively. With the current advances in deep network hardware accelerators, these networks can be combined with the sensors for a compact embedded system suitable for edge applications.Keywords
This publication has 21 references indexed in Scilit:
- Calibrating chemical multisensory devices for real world applications: An in-depth comparison of quantitative machine learning approachesSensors and Actuators B: Chemical, 2018
- Eyeriss: An Energy-Efficient Reconfigurable Accelerator for Deep Convolutional Neural NetworksIEEE Journal of Solid-State Circuits, 2016
- Cambricon-X: An accelerator for sparse neural networks2016
- Origami: A 803-GOp/s/W Convolutional Network AcceleratorIEEE Transactions on Circuits and Systems for Video Technology, 2016
- Deep Residual Learning for Image Recognition2016
- Determination Of Gas Mixture Components Using Fluctuation Enhanced Sensing And The LS-SVM Regression AlgorithmMetrology and Measurement Systems, 2015
- Long term stability of metal oxide-based gas sensors for e-nose environmental applications: An overviewSensors and Actuators B: Chemical, 2010
- CO, NO2 and NOx urban pollution monitoring with on-field calibrated electronic nose by automatic bayesian regularizationSensors and Actuators B: Chemical, 2009
- On field calibration of an electronic nose for benzene estimation in an urban pollution monitoring scenarioSensors and Actuators B: Chemical, 2008
- Support-vector networksMachine Learning, 1995