Contact stresses, pressure and area in a fixed-bearing total ankle replacement: a finite element analysis
Open Access
- 25 November 2017
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 493
Abstract
Mobile-bearing ankle implants with good clinical results continued to increase the popularity of total ankle arthroplasty to address endstage ankle osteoarthritis preserving joint movement. Alternative solutions used fixed-bearing designs, which increase stability and reduce the risk of bearing dislocation, but with a theoretical increase of contact stresses leading to a higher polyethylene wear. The purpose of this study was to investigate the contact stresses, pressure and area in the polyethylene component of a new total ankle replacement with a fixed-bearing design, using 3D finite element analysis. A three-dimensional finite element model of the Zimmer Trabecular Metal Total Ankle was developed and assembled based on computed tomography images. Three different sizes of the polyethylene insert were modeled, and a finite element analysis was conducted to investigate the contact pressure, the von Mises stresses and the contact area of the polyethylene component during the stance phase of the gait cycle. The peak value of pressure was found in the anterior region of the articulating surface, where it reached 19.8 MPa at 40% of the gait cycle. The average contact pressure during the stance phase was 6.9 MPa. The maximum von Mises stress of 14.1 MPa was reached at 40% of the gait cycle in the anterior section. In the central section, the maximum von Mises stress of 10.8 MPa was reached at 37% of the gait cycle, whereas in the posterior section the maximum stress of 5.4 MPa was reached at the end of the stance phase. The new fixed-bearing total ankle replacement showed a safe mechanical behavior and many clinical advantages. However, advanced models to quantitatively estimate the wear are need. To the light of the clinical advantages, we conclude that the presented prosthesis is a good alternative to the other products present in the market.Keywords
This publication has 25 references indexed in Scilit:
- Determination of dynamic ankle ligament strains from a computational model driven by motion analysis based kinematic dataJournal of Biomechanics, 2011
- Stresses in the ankle joint and total ankle replacement designFoot and Ankle Surgery, 2011
- Misalignment of Total Ankle Components Can Induce High Joint Contact PressuresJournal of Bone and Joint Surgery, 2010
- A randomised, controlled trial of two mobile-bearing total ankle replacementsThe Journal of Bone and Joint Surgery. British volume, 2009
- History and evolution in total ankle arthroplastyBritish Medical Bulletin, 2008
- Current Concepts Review: Total Ankle ArthroplastyFoot & Ankle International, 2008
- Simulation of polyethylene wear in ankle joint prosthesesJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2006
- Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive filmJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2006
- Finite element analysis of a total ankle replacement during the stance phase of gaitJournal of Biomechanics, 2006
- Total ankle replacement: review of the designs and of the current statusFoot and Ankle Surgery, 2000