Photon-counting versus an integrating CCD-based gamma camera: important consequences for spatial resolution
Authors:
- 25 May 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (12) , N109-N119
Abstract
Charge-coupled devices (CCDs) coupled to scintillation crystals can be used for high resolution imaging with x-rays and gamma-rays. When the CCD images can be read out fast enough, the energy and interaction position of individual gamma quanta can be estimated by real-time image analysis of scintillation light flashes ('photon counting mode'). We tested a set-up in which an electron-multiplying CCD was coupled to a 1 mm thick columnar CsI crystal by means of a fibre-optic taper. We found that, compared to light integration, photon counting improves the intrinsic spatial resolution by a factor of about 3 to 6. Applying our set-up to Tc-99m and I-125 imaging, we were able to obtain intrinsic resolutions below 60 microm (full width at half maximum). Counting losses due to overlapping of light flashes are negligible for event rates typical for biomedical radio-nuclide imaging and do strongly depend on energy window settings. Energy resolution was estimated to be approximately 35 keV FWHM for a 1:1 taper. We conclude that CCD-based gamma cameras have great potential for applications such as in vivo imaging of gamma emitters.Keywords
This publication has 17 references indexed in Scilit:
- Design and simulation of a high-resolution stationary SPECT system for small animalsPhysics in Medicine & Biology, 2004
- The high resolution gamma imager (HRGI): a CCD based camera for medical imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- A monolithic array of silicon drift detectors coupled to a single scintillator for γ-ray imaging with sub-millimeter position resolutionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Impactron-a new solid state image intensifierIEEE Transactions on Electron Devices, 2001
- The LLCCD: low-light imaging without the need for an intensifier2001
- Applications of semiconductor detectors to nuclear medicineNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- 3-D position sensitive CdZnTe gamma-ray spectrometersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- Radio-imaging for quantitative autoradiography in biologyNuclear Medicine and Biology, 1998
- CdZnTe arrays for astrophysics applications1997
- Scintillation CameraReview of Scientific Instruments, 1958