FRP-laminated Rubber Isolator: Theoretical Study and Shake Table Test on Isolated Building
- 19 May 2022
- journal article
- research article
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (5) , 1302-1323
Abstract
Performance of fiber-reinforced polymer (FRP)-laminated rubber isolators has been investigated through theoretical and experimental analyses. Effective horizontal stiffness of FRP rubber isolator is analyzed by the cyclic quasi-static experiment. A 1/3 scale shake table tests have been carried out to assess the seismic behavior and the efficiency of the FRP-laminated rubber isolator under the ground motions in different site conditions. The effective horizontal stiffness of the isolator has been derived which has been compared with the experimental results. Experimental studies have shown that FRP-laminated rubber bearings with many advantages can be applied to building structures to enhance seismic capacity.Keywords
Funding Information
- National Natural Science Foundation of China (51778160, 51878298, 52178281)
- Science and Technology Program of Guangzhou, China (201831826)
- Guangdong Provincial Key Laboratory of Modern Civil Engineering Technology (2021B1212040003)
This publication has 18 references indexed in Scilit:
- Innovative low-cost recycled rubber–fiber reinforced isolator: Experimental tests and Finite Element AnalysesEngineering Structures, 2014
- Performance of fiber-reinforced elastomeric base isolators under cyclic excitationStructural Control and Health Monitoring, 2014
- Performance of Seismic Protection Technologies during the 2011 Tohoku‐Oki EarthquakeEarthquake Spectra, 2013
- Report on the effects of seismic isolation methods from the 2011 Tohoku–Pacific earthquakeSeismic Isolation and Protective Systems, 2011
- Stability of fiber-reinforced elastomeric bearings in an unbonded applicationJournal of Composite Materials, 2011
- Testing and modeling of square carbon fiber-reinforced elastomeric seismic isolatorsStructural Control and Health Monitoring, 2007
- An equivalent linear model of lead-rubber seismic isolation bearingsEngineering Structures, 1996
- Performance of the base-isolated USC University Hospital under the 1994 Northridge earthquakeNuclear Engineering and Design, 1994
- Evaluation of seismic energy in structuresEarthquake Engineering & Structural Dynamics, 1990
- Aseismic base isolation: review and bibliographySoil Dynamics and Earthquake Engineering, 1986