In vitrocomparison of conventional film and direct digital imaging in the detection of approximal caries
Authors:
- Vm CastroVCVm Castro
- Jo KatzJKJo Katz
- Pk HardmanPHPk Hardman
- Ag GlarosAGAg Glaros
- P SpencerPSP Spencer
- 1 March 2007
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 36 (3) , 138-142
Abstract
Objectives: To compare the diagnostic accuracy of conventional film, unenhanced direct digital and inversion grayscale direct digital imaging in the detection of approximal caries. Methods: 150 approximal surfaces of extracted permanent molars and premolars were selected for the study on the basis of varying lesion depth. The teeth were radiographed using Ektaspeed Plus film; digital images were made with a Schick CMOS-APS sensor. 7 examiners evaluated 58 randomized images of each modality. Histological sectioning of the teeth was used to verify the presence and extent of decay. Results: No significant difference was found between the diagnostic accuracies of the three imaging modalities (P=0.226). Analysis of the diagnostic accuracy of the three modalities on lesion depth showed no statistically significant interaction; however, the main effect of the lesion depth was significant (Pη2=0.936). Conclusions: The overall diagnostic accuracy of the three modalities in the detection of approximal carious lesions was comparable. All three modalities performed poorly in the detection of enamel lesions.Keywords
This publication has 19 references indexed in Scilit:
- Grey-scale reversed radiographic display in the detection of approximal cariesJournal of Dentistry, 2005
- An in–vitro Evaluation of Kodak Insight and Ektaspeed Plus Film with a CMOS Detector for Natural Proximal Caries: ROC AnalysisCaries Research, 2001
- Approximal Caries Depth Assessment with Storage Phosphor versus Film RadiographyCaries Research, 2000
- Two- and three-dimensional imaging modalities for the detection of caries. A comparison between film, digital radiography and tuned aperture computed tomography (TACTTM)Dentomaxillofacial Radiology, 1999
- A comparison of a film-based and a direct digital dental radiographic system using a proximal caries model.Dentomaxillofacial Radiology, 1997
- Comparative performance of digital and conventional images for detecting proximal surface caries.Dentomaxillofacial Radiology, 1997
- Intraoral storage phosphor radiography for approximal caries detection and effect of image magnificationOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 1996
- A comparison of conventional intra-oral radiography and computer imaging techniques for the detection of proximal surface dental caries.Dentomaxillofacial Radiology, 1992
- The Use of Continuous and Discrete Confidence Judgments in Receiver Operating Characteristic Studies of Diagnostic Imaging TechniquesInvestigative Radiology, 1992
- A reappraisal of the value of the bitewing radiograph in the diagnosis of posterior approximal cariesBritish Dental Journal, 1990