Hemodynamic and Catecholamine Stress Responses to Insertion of the Combitube[registered sign], Laryngeal Mask Airway or Tracheal Intubation
Authors:
- Wolfgang OczenskiWOWolfgang Oczenski
- Herbert KrennHKHerbert Krenn
- Ashraf A. DahabaADAshraf A. Dahaba
- Maria BinderMBMaria Binder
- Irene El-Schahawi-KienzlIEIrene El-Schahawi-Kienzl
- Helmuth JellinekHJHelmuth Jellinek
- Sylvia SchwarzSSSylvia Schwarz
- Robert D. FitzgeraldRFRobert D. Fitzgerald
- 1 June 1999
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 88 (6) , 1389-1394
Abstract
In a prospective, randomized, and controlled trial, we compared the stress responses after insertion of the Combitube[registered sign] (CT; Kendall-Sheridan Catheter Corp., Argyle, NY), the laryngeal mask airway (LMA), or endotracheal intubation (ET). Seventy-five patients scheduled for routine urological or gynecological surgery were randomly allocated to one of three groups and were ventilated via either an ET, a LMA, or a CT. All three devices could be inserted easily and rapidly, providing adequate ventilation and oxygenation. Insertion of the CT was associated with a significant increase in mean maximal systolic arterial pressure (160 +/- 32 mm Hg) and diastolic arterial pressure (91 +/- 17 mm Hg) compared with ET (140 +/- 24, 78 +/- 11 mm Hg; P < 0.05, P < 0.01, respectively) or insertion of the LMA (115 +/- 33, 63 +/- 22 mm Hg, both P < 0.001). The mean maximal epinephrine and norepinephrine plasma concentrations after insertion of the CT (37.3 +/- 31.1 and 279 +/- 139 pg/mL, respectively) were significantly higher than those after ET (35.8 +/- 89.8 and 195 +/- 58 pg/mL, respectively) or insertion of a LMA (17.3 +/- 13.3 and 158 +/- 67 pg/mL, respectively). This might be attributed to the pressure of the pharyngeal cuff of the CT on the anterior pharyngeal wall. We conclude that insertion of the CT causes a pronounced stress response and that precautions should be taken when used in patients at risk of hypertensive bleeding. Implications: In this study, we showed that the hemodynamic and catecholamine stress responses after insertion of the Combitube[registered sign] (Kendall-Sheridan Catheter Corp., Argyle, NY) were significantly higher compared with laryngeal mask airway or endotracheal intubation. We conclude that the increased stress response to insertion of a Combitube[registered sign] may represent a serious hazard to patients with cardiovascular disease. (Anesth Analg 1999;88:1389-94)Keywords
This publication has 19 references indexed in Scilit:
- The Laryngeal Mask Airway Its Uses in AnesthesiologyAnesthesiology, 1993
- Cardiovascular responses to insertion of the laryngeal maskAnaesthesia, 1992
- Management of the Difficult Adult Airway With Special Emphasis on Awake Tracheal IntubationAnesthesiology, 1991
- Additional Safety Measures When Changing Endotracheal TubesAnesthesiology, 1991
- Hemodynamic and catecholamine responses to laryngoscopy with vs. without endotracheal intubationActa Anaesthesiologica Scandinavica, 1991
- Cardiovascular response to insertion of Brain's laryngeal maskAnaesthesia, 1990
- The pressor response and laryngeal mask insertionAnaesthesia, 1989
- The esophageal tracheal combitube: Preliminary results with a new airway for CPRAnnals of Emergency Medicine, 1987
- Evaluation of esophageal tracheal combitube in cardiopulmonary resuscitationCritical Care Medicine, 1987
- Difficult tracheal intubation: a retrospective studyAnaesthesia, 1987