An Adaptive Current Control Technique in Grid-tied PV System with Active Power Filter for Power Quality Improvement
- 1 October 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 187-191
Abstract
This study proposes an adaptive second order generalized integrator based quadrature signal generator-frequency locked loop (SOGI-QSG-FLL) and fuzzy tuned proportional integral (FPI) in grid interconnection of photovoltaic (PV) system with shunt power quality conditioner (SAPF) for quality of power enhancement. The SOGI-QSG-FLL adaptive controller is simple in structure, more flexible, and it has been utilized for many applications like grid synchronization, frequency estimation, and harmonic extraction. The FPI voltage controller is used to stable DC bus voltage at a reference value. The combination of both controllers gives a better performance at steady state, dynamic load, grid voltage unbalancing, voltage fall, deformed voltage, raises voltage, and eliminated load states. The frequency locked loop (FLL) used for frequency estimation; the hysteresis current controller utilized for generating PWM signals to SAPF inverter. The proposed controller executed on MATLAB/SIMULINK software platform under steady state, dynamic load, grid voltage unbalancing, sag, distorted, swell grid voltage, and load removed conditions. And the simulation results are found adequate within IEEE-519 limits.Keywords
This publication has 14 references indexed in Scilit:
- Real time harmonics estimation of distorted power system signalInternational Journal of Electrical Power & Energy Systems, 2016
- Novel structure for unbalance, reactive power and harmonic compensation based on VFF-RLS and SOGI-FLL in three phase four wire power system2015
- Fuzzy PI controlled inverter for grid interactive renewable energy systemsIET Renewable Power Generation, 2015
- ILST Control Algorithm of Single-Stage Dual Purpose Grid Connected Solar PV SystemIEEE Transactions on Power Electronics, 2014
- Real‐time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self‐tuning filterIET Power Electronics, 2014
- Application of Artificial Neural Networks for Shunt Active Power Filter ControlIEEE Transactions on Industrial Informatics, 2014
- Harmonic power compensation capacity of shunt active power filter and its relationship with design parametersIET Power Electronics, 2014
- Kalman Filter-Based Control System for Power Quality Conditioning DevicesIEEE Transactions on Industrial Electronics, 2012
- Dynamic Harmonic Analysis Through Taylor–Fourier TransformIEEE Transactions on Instrumentation and Measurement, 2010
- Detection and classification of power quality disturbances using discrete wavelet transform and wavelet networksIET Science, Measurement & Technology, 2010