Abstract
This study proposes an adaptive second order generalized integrator based quadrature signal generator-frequency locked loop (SOGI-QSG-FLL) and fuzzy tuned proportional integral (FPI) in grid interconnection of photovoltaic (PV) system with shunt power quality conditioner (SAPF) for quality of power enhancement. The SOGI-QSG-FLL adaptive controller is simple in structure, more flexible, and it has been utilized for many applications like grid synchronization, frequency estimation, and harmonic extraction. The FPI voltage controller is used to stable DC bus voltage at a reference value. The combination of both controllers gives a better performance at steady state, dynamic load, grid voltage unbalancing, voltage fall, deformed voltage, raises voltage, and eliminated load states. The frequency locked loop (FLL) used for frequency estimation; the hysteresis current controller utilized for generating PWM signals to SAPF inverter. The proposed controller executed on MATLAB/SIMULINK software platform under steady state, dynamic load, grid voltage unbalancing, sag, distorted, swell grid voltage, and load removed conditions. And the simulation results are found adequate within IEEE-519 limits.

This publication has 14 references indexed in Scilit: