The effect of using quarter individual milking system “MultiLactor” on improvement of milk performance and milk quality of different dairy cows breeds in different farms
Open Access
- 31 January 2018
- journal article
- research article
- Published by Pensoft Publishers in Emirates Journal of Food and Agriculture
- Vol. 30 (1) , 57-64
Abstract
Milking machine is an important factor in milk performance and milk quality during the course of milk removal in dairy cows. The purpose of the present study was to determine the effect of using quarter individual milking system “MultiLactor” (ML) on improvement of milk performance and milk quality of different dairy cows breeds in different farms. A quarter individual Milking system ML has a single guided tubes with a vacuum of 34 kPa, pulsation rate of 60 cycle/min and ration of 60 to 40%. The system has also a periodic air inlet and a sequential pulsation. In this study, milking data were collected from 170 Holstein Friesian cows (Farm 1), 130 Holstein Friesian (red) cows (Farm 2) and 54 Brown Swiss cows (Farm 3). Quantitative and qualitative milk data of these farms have been recorded by Association of milk records, Switzerland. The primary milking data of cows were collected during the period from 2010 to 2015 after using the new milking system. The data were later processed with Excel program and analyzed using the statistical analysis system (SAS). The results are presented as least square means with standard errors (LSM±SE) and the significant difference was set at (P<0.05). The daily milk yield during the study period from 2010 to 2015 increased significantly to 117% (from 34.64±1.23 to 40.51±1.00 kg/day/animal), 162% (from 20.29±1.37 to 30.88±0.65 kg/day/animal) and 151% (from 15.04±0.83 to 22.71±0.54 kg/day/animal) in farms 1, 2 and 3 respectively after using of ML milking system. Fat and protein content of the milk also increased during the same period of three breeds and farms. However, the results showed that the milking system ML had significant effects on the udder health status by reducing continuously somatic cell count (SCC) in milk by 54.81%, 51.54% and 51.66% in farm 1, 2 and 3 respectively during the study period. Furthermore, Lactation number of the cows were continuously increased in the study during the same period. In conclusion, after 5 years of using ML, it has been shown that a quarter individual milking machine was adapted to the physiological requirements of dairy farms and different breeds and the milk removal with ML brings better quantity and quality of milk in terms of improved milk performance, fat %, protein % and lower number of SCC in the milk.Keywords
This publication has 18 references indexed in Scilit:
- Effects of quarter individual and conventional milking systems on teat conditionPreventive Veterinary Medicine, 2014
- Invited review: Effect of udder health management practices on herd somatic cell countJournal of Dairy Science, 2011
- Management systems with extended milking intervals in ruminants: Regulation of production and quality of milk1,2Journal of Animal Science, 2008
- Sources of Variation in Milk Flow Characteristics at Udder and Quarter LevelsJournal of Dairy Science, 2006
- Effects of Dry Period Length on Milk Yield and Mammary Epithelial CellsJournal of Dairy Science, 2004
- On the relationship between lactational performance and health: is it yield or metabolic imbalance that cause production diseases in dairy cattle? A position paperLivestock Production Science, 2003
- Fractionized Milk Composition During Removal of Colostrum and Mature MilkJournal of Dairy Science, 2003
- Local control of mammary development and functionReviews of Reproduction, 1998
- Animal models for the study of milk secretionJournal of Mammary Gland Biology and Neoplasia, 1996
- Autocrine control in milk secretionThe Journal of Agricultural Science, 1990