Tissue Doppler Imaging Detects Impaired Biventricular Performance Shortly After Congenital Heart Defect Surgery
- 22 September 2012
- journal article
- research article
- Published by Springer Nature in Pediatric Cardiology
- Vol. 34 (3) , 630-638
Abstract
Cardiac surgery with cardiopulmonary bypass is associated with the development of a systemic inflammatory response, which can lead to myocardial damage. However, knowledge concerning the time course of ventricular performance deterioration and restoration after correction of a congenital heart defect (CHD) in pediatric patients is sparse. Therefore, the authors perioperatively quantified left ventricular (LV) and right ventricular (RV) performance using echocardiography. Their study included 141 patients (ages 0–18 years) undergoing CHD correction and 40 control subjects. The study assessed LV systolic performance (fractional shortening) and diastolic performance (mitral Doppler flow) in combination with RV systolic performance [tricuspid annular plane systolic excursion (TAPSE)] and diastolic performance (tricuspid Doppler flow). Additionally, systolic (S′) and diastolic (E′, A′, E/E′) tissue Doppler imaging (TDI) measurements were obtained at the LV lateral wall, the interventricular septum, and the RV free wall. Echocardiographic studies were performed preoperatively, 1 day postoperatively, and at hospital discharge after 9 ± 5 days. Although all LV echocardiographic measurements showed a deterioration 1 day after surgery, only LV TDI measurements were impaired in patients at discharge versus control subjects (S′: 5.7 ± 2.0 vs 7.1 ± 2.7 cm/s; E′: 9.8 ± 3.9 vs 13.7 ± 5.1 cm/s; E/E′: 12.2 ± 6.4 vs 8.8 ± 4.3; p < 0.05). In the RV, TAPSE and RV TDI velocities also were impaired in patients at discharge versus control subjects (TAPSE: 9 ± 3 vs 17 ± 5 mm; S′: 5.2 ± 1.7 vs 11.4 ± 3.4 cm/s; E′: 7.3 ± 2.5 vs 16.3 ± 5.2 cm/s; E/E′: 12.5 ± 6.8 vs 4.8 ± 1.9; p < 0.05). Furthermore, longer aortic cross-clamp times were associated with more impaired postoperative LV and RV performance (p < 0.05). In conclusion, both systolic and diastolic biventricular performances were impaired shortly after CHD correction. This impairment was detected only by TDI parameters and TAPSE. Furthermore, a longer-lasting negative influence of cardiopulmonary bypass on myocardial performance was suggested.Keywords
This publication has 26 references indexed in Scilit:
- Decreased Right Ventricular Lateral Wall Velocities Early after Cardiac SurgeryEchocardiography, 2011
- Tissue Doppler imaging following paediatric cardiac surgery: early patterns of change and relationship to outcomeInteractive CardioVascular and Thoracic Surgery, 2009
- Risks and Predictors of Blood Transfusion in Pediatric Patients Undergoing Open Heart OperationsThe Annals of Thoracic Surgery, 2009
- Technological advances in tissue Doppler imaging echocardiographyHeart, 2008
- Haemodialysis: effects of acute decrease in preload on tissue Doppler imaging indices of systolic and diastolic function of the left and right ventriclesEuropean Heart Journal - Cardiovascular Imaging, 2008
- Usefulness of tissue Doppler imaging for estimation of left ventricular filling pressures in patients with systolic and diastolic heart failureThe American Journal of Cardiology, 2005
- Analysis of right ventricular Doppler tissue imaging and load dependence in patients undergoing percutaneous closure of atrial septal defectThe American Journal of Cardiology, 2004
- Early and long term outcome of the arterial switch operation for transposition of the great arteries: predictors and functional evaluationEuropean Journal of Cardio-Thoracic Surgery, 2002
- Clinical Utility of Doppler Echocardiography and Tissue Doppler Imaging in the Estimation of Left Ventricular Filling PressuresCirculation, 2000
- Assessment of right ventricular function using two-dimensional echocardiographyAmerican Heart Journal, 1984