The Effects of Different Antigen–Antibody Pairs on the Results of 20 Min ELISA and 8 Min Chromatographic Paper Test for Quantitative Detection of Acetamiprid in Vegetables
Open Access
- 5 September 2022
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 12 (9) , 730
Abstract
To establish rapid, high-sensitive, quantitative detection of ACP residues in vegetables. A 1G2 cell clone was selected as the most sensitive for anti-ACP antibody production following secondary immunization, cell fusion, and screening. The affinity of the 1G2 antibody to each of the four coating agents (imidacloprid–bovine serum albumin [BSA], thiacloprid–BSA, imidaclothiz–BSA, and ACP-BSA) was determined using a 20 min enzyme-linked immunosorbent assay (ELISA). The half maximal inhibitory concentration (IC50) was 0.51–0.62 ng/mL, showing no significant difference in affinity to different antigens. However, we obtained IC50 values of 0.58 and 1.40 ng/mL on the linear regression lines for 1G2 anti-ACP antibody/imidacloprid–BSA and 1G2 anti-ACP antibody/thiacloprid–BSA, respectively, via quantum dot (QD)-based immunochromatography. That is, the 1G2 antibody/imidacloprid–BSA pair (the best combination) was about three times more sensitive than the 1G2 antibody/thiacloprid–BSA pair in immunochromatographic detection. The best combination was used for the development of an 8 min chromatographic paper test. With simple and convenient sample pretreatment, we achieved an average recovery of 75–117%. The coefficient of variation (CoV) was <25% for all concentrations tested, the false–positive rate was <5%, the false–negative rate was 0%, and the linear range of the method was 50–1800 μg/kg. These performance metrics met the ACP detection standards in China, the European Union (EU), and the United States (US). In summary, in this study, we established an 8 min QD-based immunochromatographic stripe for the rapid and accurate quantitative determination of ACP residues in vegetables.Keywords
This publication has 29 references indexed in Scilit:
- A facile label-free colorimetric aptasensor for acetamiprid based on the peroxidase-like activity of hemin-functionalized reduced graphene oxideBiosensors and Bioelectronics, 2015
- Development of ultrasensitive direct chemiluminescent enzyme immunoassay for determination of aflatoxin M1 in milkFood Chemistry, 2014
- Rapid and sensitive lateral flow immunoassay for influenza antigen using fluorescently-doped silica nanoparticlesMicrochimica Acta, 2013
- Highly sensitive and selective novel core–shell molecularly imprinted polymer based on NaYF4: Yb3+, Er3+ upconversion fluorescent nanorodsRSC Advances, 2013
- An ultra-sensitive monoclonal antibody-based competitive enzyme immunoassay for aflatoxin M1 in milk and infant milk productsFood Chemistry, 2011
- Production of ultrasensitive generic monoclonal antibodies against major aflatoxins using a modified two-step screening procedureAnalytica Chimica Acta, 2009
- Immunoassay for acetamiprid detection: application to residue analysis and comparison with liquid chromatographyAnalytical and Bioanalytical Chemistry, 2006
- Development of an Immunoassay-Based Lateral Flow Dipstick for the Rapid Detection of Aflatoxin B1 in Pig FeedJournal of Agricultural and Food Chemistry, 2005
- Pesticides report 33. Immunoassays for residue analysis of agrochemicals: Proposed guidelines for precision, standardization and quality control (Technical Report)Pure and Applied Chemistry, 1995
- Purification of IgG monoclonal antibody by caprylic acid precipitationJournal of Immunological Methods, 1983