Bone Compaction Enhances Fixation of Weightbearing Titanium Implants
Authors:
- Søren KoldSKSøren Kold
- Ole RahbekOROle Rahbek
- Marianne VestermarkMVMarianne Vestermark
- Søren OvergaardSOSøren Overgaard
- Kjeld SøballeKSKjeld Søballe
- 1 February 2005
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 431 (431) , 138-144
Abstract
Implant stability is crucial for implant survival. A new surgical technique, compaction, has increased in vitro implant stability and in vivo fixation of nonweightbearing implants. However, the in vivo effects of compaction on weightbearing implants are unknown. As implants inserted clinically are weightbearing, the effects of compaction on weightbearing implants were examined. The hypothesis was that compaction would increase implant fixation compared with conventional drilling. Porous-coated titanium implants were inserted bilaterally into the weightbearing portion of the femoral condyles of dogs. In each dog, one knee had the implant cavity prepared with drilling, and the other knee was prepared with compaction. Eight dogs were euthanized after 2 weeks, and eight dogs were euthanized after 4 weeks. Femoral condyles from an additional eight dogs represented Time 0. Compacted specimens had higher bone-implant contact and periimplant bone density at 0 and 2 weeks, but not at 4 weeks. A biphasic response of compaction was found with a pushout test, as compaction increased ultimate shear strength and energy absorption at 0 and 4 weeks, but not at 2 weeks. This biphasic response indicates that compaction enhances implant fixation by mechanical and biological mechanisms. Therefore, compaction might have potential value in total joint replacement in the future.Keywords
This publication has 36 references indexed in Scilit:
- Femoral Fracture Risk in Hip Arthroplasty: Smooth Versus Toothed InstrumentsClinical Orthopaedics and Related Research, 2003
- Compacted cancellous bone has a spring-back effectActa Orthopaedica, 2003
- Transforming growth factor-β1 adsorbed to tricalciumphosphate coated implants increases peri-implant bone remodelingBiomaterials, 2001
- Cement penetration in the proximal femur does not depend on broach surface finishActa Orthopaedica, 2001
- Load-Bearing Increases New Bone Formation in Impacted and Morselized AllograftsClinical Orthopaedics and Related Research, 2000
- Relative effects of wound healing and mechanical stimulus on early bone response to porous‐coated implantsJournal of Orthopaedic Research, 1996
- Efficacy of autograft and freeze-dried allograft to enhance fixation of porous coated implants in the presence of interface gapsJournal of Orthopaedic Research, 1992
- A Method for Preparing and Staining Histological Sections Containing Titanium Implants for Light MicroscopyStain Technology, 1989
- Some new, simple and efficient stereological methods and their use in pathological research and diagnosisAPMIS, 1988
- A quantitative histologic study of bone turnover in young adult beaglesThe Anatomical Record, 1982