Newborn Pulse Oximetry Screening: Which Algorithm Is Best?
Authors:
Open Access
- 1 November 2016
- journal article
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 138 (5) , e20161206
Abstract
* Abbreviations: FP — : false positive POS — : pulse oximetry screening CCHD — : critical congenital heart defect Pulse oximetry screening (POS) is an accepted test that improves detection of critical congenital heart defects (CCHD).1 Although outcome data are lacking, there is agreement among clinicians that POS identifies infants with CCHD before discharge. After consideration by an expert workgroup, POS was adopted onto the US Recommended Uniform Screening Panel,2 and other countries have either introduced, or are considering introducing, POS.1 Despite this, there is considerable variation in screening, particularly the algorithm used.3 Differences include (1) pre- and postductal saturations (right hand and either foot) versus single postductal measurement (foot only) and (2) timing of screening (ie, before or after 24 hours). In algorithms using 2 limb measurements, there are also differences: inclusion of saturations <95% in 1 or both limbs and the absolute value of the differential between the 2 in determining positive results.1 So which algorithm is best? When evaluating algorithms, it is important to consider sensitivity, specificity, false-positive (FP) and false-negative rate. It is also vital that screening leads to timely diagnosis (ie, before presentation with acute collapse). Meta-analysis of POS studies shows that overall, the test has moderate sensitivity (∼75%) and high specificity (99.8%), with no significant difference in sensitivity between pre/–post versus postductal testing or timing.3 However, analysis of raw saturation data from infants who had both limb measurements shows that some infants with CCHD would be missed by postductal testing alone.1 In addition, the FP rate is significantly higher with earlier testing (<24 hours).3 These factors were deemed … Address for correspondence Andrew K. Ewer, Neonatal Unit, Birmingham Women’s Hospital, Edgbaston, Birmingham UK. B15 2TG. E-mail: a.k.ewer{at}bham.ac.ukKeywords
This publication has 9 references indexed in Scilit:
- Nordic pulse oximetry screening – implementation status and proposal for uniform guidelinesActa Paediatrica, 2014
- The impact of routine predischarge pulse oximetry screening in a regional neonatal unitArchives of Disease in Childhood - Fetal and Neonatal Edition, 2014
- Results From the New Jersey Statewide Critical Congenital Heart Defects Screening ProgramPediatrics, 2013
- Review of pulse oximetry screening for critical congenital heart defects in newborn infantsCurrent Opinion in Cardiology, 2013
- Pulse oximetry screening for critical congenital heart defects in asymptomatic newborn babies: a systematic review and meta-analysisThe Lancet, 2012
- Strategies for Implementing Screening for Critical Congenital Heart DiseasePediatrics, 2011
- Pulse oximetry screening for congenital heart defects in newborn infants (PulseOx): a test accuracy studyThe Lancet, 2011
- Effectiveness of neonatal pulse oximetry screening for detection of critical congenital heart disease in daily clinical routine—results from a prospective multicenter studyEuropean Journal of Pediatrics, 2010
- Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39 821 newbornsBMJ, 2009