Abstract
To report on the use of a supplemental medial endosteal implant to prevent varus collapse and screw cutout in proximal humerus fractures treated with a laterally placed locking plate. Twenty-seven patients meeting study inclusion criteria were included in the study. Follow-up averaged 63.1 weeks (minimum 37 weeks and maximum 120 weeks). All patients were either older than 70 years or had sustained a proximal humerus fracture with medial comminution. Using the anterolateral acromial approach, a proximal humeral locking plate augmented with a medial endosteal implant (fibular allograft in 23 patients and semitubular plate in 4 patients) was used for fixation. Intraoperative fluoroscopic images and the most recent follow-up radiographs were used to measure the head-shaft angle and loss of height between the implant and the articular surface. Only 1 of 27 patients had significant loss of reduction with collapse of the fracture into varus (4.2 mm change). Ninety-six percent of patients maintained their original reduction with an average loss of height of 1.2 mm and an average change in shaft-head angle of 2.2 degrees. There were no implant failures or screw perforations of the articular surface and no radiographic or clinical evidence of AVN. Use of a medial endosteal implant as a supplement to a lateral locking plate is effective in maintaining operative reduction, preventing varus collapse, and implant failure in fractures with medial comminution and/or poor bone quality. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 17 references indexed in Scilit:
- Open Reduction and Internal Fixation of Proximal Humeral Fractures with Use of the Locking Proximal Humerus PlateJournal of Bone and Joint Surgery, 2009
- Open Reduction and Internal Fixation of Proximal Humerus Fractures Using a Proximal Humeral Locked Plate: A Prospective Multicenter AnalysisJournal of Orthopaedic Trauma, 2009
- Angular Stable Fixation of Proximal Humeral FracturesJournal of Trauma: Injury, Infection & Critical Care, 2009
- Early Complications in Proximal Humerus Fractures (OTA Types 11) Treated With Locked PlatesJournal of Orthopaedic Trauma, 2008
- Displacement/Screw Cutout After Open Reduction and Locked Plate Fixation of Humeral FracturesJournal of Bone and Joint Surgery, 2008
- Locked vs. unlocked plate osteosynthesis of the proximal humerus – A biomechanical studyClinical Biomechanics, 2007
- Biomechanical Analysis of Blade Plate Versus Locking Plate Fixation for a Proximal Humerus Fracture: Comparison Using Cadaveric and Synthetic HumeriJournal of Orthopaedic Trauma, 2006
- The Geographic Incidence and Treatment Variation of Common Fractures of Elderly PatientsJournal of the American Academy of Orthopaedic Surgeons, 2006
- Locking plates improve torsional resistance in the stabilization of three-part proximal humeral fracturesJournal of Shoulder and Elbow Surgery, 2006
- Nonunions of the HumerusClinical Orthopaedics and Related Research, 2004