A New Approach for the Determination of Dose Rate and Radioactivity for Detected Gamma Nuclides Using an Environmental Radiation Monitor Based on an NaI(Tl) Detector
Authors:
- Chang-Jong KimCKChang-Jong Kim
- Kyo-Sun LimKLKyo-Sun Lim
- Wanno LeeWLWanno Lee
- Hyon-Sock ChangHCHyon-Sock Chang
- Kun Ho ChungKCKun Ho Chung
- 1 October 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Health Physics
- Vol. 113 (4) , 304-314
Abstract
To expand the application of dose rate spectroscopy to the environment, the method using an environmental radiation monitor (ERM) based on a 3" × 3" NaI(Tl) detector was used to perform real-time monitoring of the dose rate and radioactivity for detected gamma nuclides in the ground around an ERM. Full-energy absorption peaks in the energy spectrum for dose rate were first identified to calculate the individual dose rates of 214Bi, 228Ac, 208Tl, and 40K distributed in the ground through interference correction because of the finite energy resolution of the NaI(Tl) detector used in an ERM. The radioactivity of the four natural radionuclides was then calculated from the in situ calibration factor—that is, the dose rate per unit curie—of the used ERM for the geometry of the ground in infinite half-space, which was theoretically estimated by Monte Carlo simulation. By an intercomparison using a portable HPGe and samples taken from the ground around an ERM, this method to calculate the dose rate and radioactivity of four nuclides using an ERM was experimentally verified and finally applied to remotely monitor them in real-time in the area in which the ERM had been installed.Keywords
This publication has 11 references indexed in Scilit:
- Validation of the quantification of natural radionuclides in raw materials and by-products using gamma-ray spectrometryAccreditation and Quality Assurance, 2016
- In situ gamma-ray spectrometry in the environment using dose rate spectroscopyRadiation Physics and Chemistry, 2016
- Application of the dose rate spectroscopy to the dose-to-curie conversion method using a NaI(Tl) detectorRadiation Physics and Chemistry, 2015
- Feasibility on the spectrometric determination of the individual dose rate for detected gamma nuclides using the dose rate spectroscopyRadiation Physics and Chemistry, 2014
- Determinations of the Exposure Rate Using a NaI(Tl) Detector of the Environmental Radiation MonitorJournal of Nuclear Fuel Cycle and Waste Technology, 2013
- Application of the dose conversion factor for a NaI(Tl) detector to the radwaste drum assayRadiation Measurements, 2011
- Electronic dose conversion technique using a NaI(Tl) detector for assessment of exposure dose rate from environmental radiationIEEE Transactions on Nuclear Science, 1998
- Calibration Factors for Ge Detectors Used for Field SpectrometryHealth Physics, 1988
- Environmental Gamma-Ray Exposure Rates Measured byIn-SituGe(Li) SpectrometerJournal of Nuclear Science and Technology, 1980
- A Spectrometric Method for Measurement of Low-level Gamma Exposure DoseHealth Physics, 1966