Influence of Volumetric Shrinkage and Curing Light Intensity on Proximal Contact Tightness of Class II Resin Composite Restorations: In Vitro Study
Authors:
- H El-ShamyHEH El-Shamy
- Mh SaberMSMh Saber
- Ce DörferCDCe Dörfer
- W El-BadrawyWEW El-Badrawy
- Bac LoomansBLBac Loomans
- 1 March 2012
- journal article
- research article
- Published by Operative Dentistry in Operative Dentistry
- Vol. 37 (2) , 205-210
Abstract
SUMMARY: Background: Proximal contact tightness of class II resin composite restorations is influenced by a myriad of factors. Previous studies investigated the role of matrix band type and thickness, consistency of resin composite, and technique of placement. However, the effect of volumetric shrinkage of resin and intensity of curing light has yet to be determined. Thus, the aim of this study was to identify the influence of these factors on the proximal contact tightness when restoring class II cavity preparations in vitro.Methods: Sixty artificial molars were restored with either a low-shrinkage (Filtek Silorane, 3M ESPE) or a conventional (Z100, 3M ESPE) composite and polymerized with low-intensity (Smartlite IQ2, Dentsply) or high-intensity light curing units (DemiTM, Kerr). Proximal contact tightness was measured using the Tooth Pressure Meter. Data were statistically analyzed using one-way analysis of variance and Tukey post hoc test.Results: Use of low-shrinkage composite (Filtek Silorane) resulted in significantly tighter proximal contacts compared to the use of conventional composite (Z100) when cured with the same polymerization unit (p<0.001). Moreover, the low-intensity curing unit (IQ2) resulted in significantly tighter contacts than the high-intensity unit when material is constant (p<0.001).Conclusions: Low-shrinkage resin composite and low curing light intensity is associated with tighter proximal contact values.Keywords
This publication has 23 references indexed in Scilit:
- Evaluation of Proximal Contact Tightness of Class II Resin Composite RestorationsOperative Dentistry, 2010
- A Clinical Study on Interdental Separation TechniquesOperative Dentistry, 2007
- Comparison of Proximal Contacts of Class II Resin Composite Restorations In VitroOperative Dentistry, 2006
- Comparison of Composite Curing Parameters: Effects of Light Source and Curing Mode on Conversion, Temperature Rise and Polymerization ShrinkageOperative Dentistry, 2006
- Factors involved in the development of polymerization shrinkage stress in resin-composites: A systematic reviewDental Materials, 2005
- Shrinkage behavior of a resin-based composite irradiated with modern curing unitsDental Materials, 2005
- Siloranes in dental compositesDental Materials, 2005
- Contraction Stress Related to Degree of Conversion and Reaction KineticsJournal of Dental Research, 2002
- Setting Stress in Composite Resin in Relation to Configuration of the RestorationJournal of Dental Research, 1987
- Cusp movement in molar teeth using dentine adhesives and composite filling materialsBiomaterials, 1987