Whole-body diffusion magnetic resonance imaging with simultaneous multi-slice excitation in children and adolescents
Open Access
- 15 March 2023
- journal article
- research article
- Published by Springer Nature in Pediatric Radiology
- Vol. 53 (7) , 1485-1496
Abstract
Background: Whole-body magnetic resonance imaging (WB-MRI) is an increasingly used guideline-based imaging modality for oncological and non-oncological pathologies during childhood and adolescence. While diffusion-weighted imaging (DWI), a part of WB-MRI, enhances image interpretation and improves sensitivity, it also requires the longest acquisition time during a typical WB-MRI scan protocol. Interleaved short tau inversion recovery (STIR) DWI with simultaneous multi-slice (SMS) acquisition is an effective way to speed up examinations. Objective: In this study of children and adolescents, we compared the acquisition time, image quality, signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) values of an interleaved STIR SMS-DWI sequence with a standard non-accelerated DWI sequence for WB-MRI. Materials and methods: Twenty children and adolescents (mean age: 13.9 years) who received two WB-MRI scans at a maximum interval of 18 months, consisting of either standard DWI or SMS-DWI MRI, respectively, were included. For quantitative evaluation, the signal-to-noise ratio (SNR) was determined for b800 images and ADC maps of seven anatomical regions. Image quality evaluation was independently performed by two experienced paediatric radiologists using a 5-point Likert scale. The measurement time per slice stack, pause between measurements including shim and total measurement time of DWI for standard DWI and SMS-DWI were extracted directly from the scan data. Results: When including the shim duration, the acquisition time for SMS-DWI was 43% faster than for standard DWI. Qualitatively, the scores of SMS-DWI were higher in six locations in the b800 images and four locations in the ADC maps. There was substantial agreement between both readers, with a Cohen’s kappa of 0.75. Quantitatively, the SNR in the b800 images and the ADC maps did not differ significantly from one another. Conclusion: Whole body-MRI with SMS-DWI provided equivalent image quality and reduced the acquisition time almost by half compared to the standard WB-DWI protocol.Keywords
Funding Information
- Universitätsklinikum Jena
This publication has 34 references indexed in Scilit:
- Improving diffusion MRI using simultaneous multi-slice echo planar imagingNeuroImage, 2012
- Musculoskeletal manifestations of sickle cell disease, diagnosis with whole body MRIEgyptian Journal of Radiology and Nuclear Medicine, 2012
- Diffusion MR Imaging for Monitoring of Treatment ResponseMagnetic Resonance Imaging Clinics of North America, 2011
- Whole-body diffusion-weighted imaging for staging malignant lymphoma in childrenPediatric Radiology, 2010
- Diffusion tensor imaging of the kidney at 3 tesla: normative values and repeatability of measurements in healthy volunteersDiagnostic and Interventional Radiology, 2010
- Whole-body MRI in children: Current status and future applicationsEuropean Journal of Radiology, 2008
- Ganzkörper-MRT bei Langerhans-Zell-Histiozytose im Kindes- und Jugendalter zur Beurteilung des SkelettsystemsRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2008
- ADC measurements at low and high b values: insight into normal brain structure with clinical DWIMagnetic Resonance Imaging, 2008
- Total-body MR-imaging in oncologyEuropean Radiology, 2006
- Simultaneous Multislice imaging (SIMUSIM) for improved cardiac imagingMagnetic Resonance in Medicine, 1989