Early revision among 12,179 hip prostheses: A comparison of 10 different brands reported to the Norwegian Arthroplasty Register, 1987-1993
Authors:
Open Access
- 1 January 1995
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 66 (6) , 487-493
Abstract
On the basis of data from the Norwegian Arthroplasty Register during the period 1987-1993, we have compared times to revision for 10 different cemented total hip prostheses. A total of 11,169 patients, with 12,179 primary total hip replacements (THRs), performed with high viscosity cement for primary arthrosis and followed for a maximum of 6.4 years, were included in this study. The Kaplan-Meier estimate of the overall percentage revised after 5 years was 2.5 (95% Confidence Interval: 2.1-3.0). For the Charnley prosthesis (n6,694), 2.9% were revised after 5 years (95% CI: 2.3-3.4). Using Cox regression to adjust for gender, age, type of cement and use of systemic antibiotic prophylaxis, the Charnley prosthesis was compared with the 9 other brands. The revision rate for the SpectrodlTH combination (Spectron acetabulum, ITH femur) (n 1,034) was only 0.35 (p 0.04) times that of the Charnley prostheses. The EliteKharnley combination (Elite acetabulum, Charnley femur) (n 507) and the Mirller Type prosthesis (n 11 6) showed poorer results with failure rates 2.3 (p 0.01) and 2.7 times (p 0.04) that of Charnley, respectively. Although the overall results for cemented THRs in general were good, clinically important differences in revision rates were demonstrated among the cemented prosthesis brands. Our findings underline the need for careful evaluation of different total hip replacements.Keywords
This publication has 12 references indexed in Scilit:
- The effect of the type of cement on early revision of Charnley total hip prostheses. A review of eight thousand five hundred and seventy-nine primary arthroplasties from the Norwegian Arthroplasty Register.Journal of Bone and Joint Surgery, 1995
- Direct modulation of osteoblastic activity with estrogen.Journal of Bone and Joint Surgery, 1994
- Current Concepts in Orthopaedic Biomaterials and Implant FixationJournal of Bone and Joint Surgery, 1993
- The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles.Journal of Bone and Joint Surgery, 1993
- Prognosis of total hip replacement in Sweden: Follow-up of 92,675 operations performed 1978–1990Acta Orthopaedica, 1993
- Early and late loosening of the acetabular cup after low-friction arthroplasty.Journal of Bone and Joint Surgery, 1992
- Aseptic loosening of straight-and curved-stem Müller femoral prosthesesArchives of orthopaedic and trauma surgery, 1991
- Survival of the Charnley hip in coxarthrosis: A 10–15-year follow-up of 629 casesActa Orthopaedica, 1991
- A critique of the methodologies used in clinical studies of hip-joint arthroplasty published in the English-language orthopaedic literature.Journal of Bone and Joint Surgery, 1988
- A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties.Journal of Bone and Joint Surgery, 1982