Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4
Authors:
- L GrevillotLGL Grevillot
- T FrissonTFT Frisson
- D ManevalDMD Maneval
- N ZahraNZN Zahra
- J-N BadelJBJ-N Badel
- D SarrutDSD Sarrut
- 20 January 2011
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (4) , 903-918
Abstract
The GEANT4-based GATE Monte Carlo (MC) platform was initially focused on PET and SPECT simulations. The new release v6.0 (February 2010) proposes new tools dedicated for radiation therapy simulations. In this work, we investigated some part of this extension and proposed a general methodology for Linac simulations. Details of the modeling of a 6 MV photon beam delivered by an Elekta Precise Linac, with radiation fields ranging from 5 × 5 to 30 × 30 cm(2) at the isocenter are presented. Comparisons were performed with measurements in water. The simulations were performed in two stages: first, the patient-independent part was simulated and a phase space (PhS) was built above the secondary collimator. Then, a multiple source model (MSM) derived from the PhS was proposed to simulate the photon fluence interacting with the patient-dependent part. The selective bremsstrahlung splitting (SBS) variance reduction technique proposed in GATE was used in order to speed up the accelerator head simulation. Further investigations showed that the SBS can be safely used without biasing the simulations. Additional comparisons with full simulations performed on the EGEE grid, in a single stage from the electron source to the water phantom, allowed the evaluation of the MSM. The proposed MSM allowed for calculating depth dose and transverse profiles in 48 hours on a single 2.8 GHz CPU, with a statistical uncertainty of 0.8% for a 10 × 10 cm(2) radiation field, using voxels of 5 × 5 × 5 mm(3). Good agreement between simulations and measurements in water was observed, with dose differences of about 1% and 2% for depth doses and dose profiles, respectively. Additional gamma index comparisons were performed; more than 90% of the points for all simulations passed the 3%/3 mm gamma criterion. To our knowledge, this feasibility study is the first one illustrating the potential of GATE for external radiotherapy applications.Keywords
This publication has 36 references indexed in Scilit:
- GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapyPhysics in Medicine & Biology, 2011
- Influence of Geant4 parameters on dose distribution and computation time for carbon ion therapy simulationPhysica Medica, 2010
- Optimization of GEANT4 settings for Proton Pencil Beam Scanning simulations using GATENuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2010
- Simulation of PIXSCAN, a photon counting micro-CT for small animal imagingJournal of Instrumentation, 2009
- Validation of a dose deposited by low-energy photons using GATE/GEANT4Physics in Medicine & Biology, 2008
- Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planningMedical Physics, 2007
- Reporting and analyzing statistical uncertainties in Monte Carlo–based treatment planningInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Accuracy of the photon and electron physics in GEANT4 for radiotherapy applicationsMedical Physics, 2005
- Application of GEANT4radiation transport toolkit to dose calculations in anthropomorphic phantomsApplied Radiation and Isotopes, 2004
- Large efficiency improvements in BEAMnrc using directional bremsstrahlung splittingMedical Physics, 2004