Simulating movements of daily living in robot-assisted total hip arthroplasty with 3D modelling
Open Access
- 2 June 2023
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (6) , 416-423
Abstract
Aims: Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in total hip arthroplasty (THA). Commonly, preoperative protocols simulate two functional positions (standing and relaxed sitting) but do not consider other common positions that may increase postoperative impingement and possible dislocation. This study investigates the feasibility of simulating commonly encountered positions, and positions with an increased risk of impingement, to lower postoperative impingement risk in a CT-based 3D model.Methods: A robotic arm-assisted arthroplasty planning platform was used to investigate 11 patient positions. Data from 43 primary THAs were used for simulation. Sacral slope was retrieved from patient preoperative imaging, while angles of hip flexion/extension, hip external/internal rotation, and hip abduction/adduction for tested positions were derived from literature or estimated with a biomechanical model. The hip was placed in the described positions, and if impingement was detected by the software, inspection of the impingement type was performed.Results: In flexion, an overall impingement rate of 2.3% was detected for flexed-seated, squatting, forward-bending, and criss-cross-sitting positions, and 4.7% for the ankle-over-knee position. In extension, most hips (60.5%) were found to impinge at or prior to 50° of external rotation (pivoting). Many of these impingement events were due to a prominent ischium. The mean maximum external rotation prior to impingement was 45.9° (15° to 80°) and 57.9° (20° to 90°) prior to prosthetic impingement. No impingement was found in standing, sitting, crossing ankles, seiza, and downward dog.Conclusion: This study demonstrated that positions of daily living tested in a CT-based 3D model show high rates of impingement. Simulating additional positions through 3D modelling is a low-cost method of potentially improving outcomes without compromising patient safety. By incorporating CT-based 3D modelling of positions of daily living into routine preoperative protocols for THA, there is the potential to lower the risk of postoperative impingement events.Cite this article: Bone Jt Open 2023;4(6):416–423.Keywords
This publication has 20 references indexed in Scilit:
- Adoption of Robotic vs Fluoroscopic Guidance in Total Hip Arthroplasty: Is Acetabular Positioning Improved in the Learning Curve?The Journal of Arthroplasty, 2017
- A Novel Approach for Dynamic Testing of Total Hip Dislocation under Physiological ConditionsPLOS ONE, 2015
- Dislocation Following Total Hip ReplacementDeutsches Ärzteblatt international, 2014
- Comparison of Robotic-assisted and Conventional Acetabular Cup Placement in THA: A Matched-pair Controlled StudyClinical Orthopaedics and Related Research, 2014
- Dislocation following total hip replacementThe Bone & Joint Journal, 2013
- A Comparison between Robotic-assisted and Manual Implantation of Cementless Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2010
- Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer‐aided design simulationJournal of Orthopaedic Research, 1998
- Dislocation in total hip arthroplasties.1980
- Dislocation in Total Hip ArthroplastiesClinical Orthopaedics and Related Research, 1980
- Dislocation and Instability Complicating Low Friction Arthroplasty of the Hip JointClinical Orthopaedics and Related Research, 1976