Validation of 3D Knee Kinematics during Gait on Treadmill with an Instrumented Knee Brace
Open Access
Abstract
To test a novel instrumented knee brace intended for use as a rehabilitation system, based on inertial measurement units (IMU) to monitor home-based exercises, the device was compared to the gold standard of motion analysis. The purpose was to validate a new calibration method through functional tasks and assessed the value of adding magnetometers for motion analysis. Thirteen healthy young adults performed a 60-second gait test at a comfortable walking speed on a treadmill. Knee kinematics were captured simultaneously, using the instrumented knee brace and an optoelectronic camera system (OCS). The intraclass correlation coefficient (ICC) showed excellent reliability for the three axes of rotation with and without magnetometers, with values ranging between 0.900 and 0.972. Pearson’s r coefficient showed good to excellent correlation for the three axes, with the root mean square error (RMSE) under 3° with the IMUs and slightly higher with the magnetometers. The instrumented knee brace obtained certain clinical parameters, as did the OCS. The instrumented knee brace seems to be a valid tool to assess ambulatory knee kinematics, with an RMSE of <3°, which is sufficient for clinical interpretations. Indeed, this portable system can obtain certain clinical parameters just as well as the gold standard of motion analysis. However, the addition of magnetometers showed no significant advantage in terms of enhancing accuracy.Keywords
Funding Information
- company marketing the instrumented knee brace, Ted Orthopedics
This publication has 29 references indexed in Scilit:
- 25 years of lower limb joint kinematics by using inertial and magnetic sensors: A review of methodological approachesGait & Posture, 2017
- Quaternion-Based Complementary Filter for Attitude Determination of a SmartphoneIEEE Sensors Journal, 2016
- Validity of an inertial measurement unit to assess pelvic orientation angles during gait, sit–stand transfers and step-up transfers: Comparison with an optoelectronic motion capture system *Medical Engineering & Physics, 2015
- Keeping a Good Attitude: A Quaternion-Based Orientation Filter for IMUs and MARGsSensors, 2015
- Soft tissue artifact distribution on lower limbs during treadmill gait: Influence of skin markers' location on cluster designJournal of Biomechanics, 2015
- Cross-Talk Correction Method for Knee Kinematics in Gait Analysis Using Principal Component Analysis (PCA): A New ProposalPLOS ONE, 2014
- Is gait variability reliable? An assessment of spatio-temporal parameters of gait variability during continuous overground walkingGait & Posture, 2014
- The use of inertial sensors system for human motion analysisPhysical Therapy Reviews, 2010
- Magnetic distortion in motion labs, implications for validating inertial magnetic sensorsGait & Posture, 2009
- Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation systemComputer Aided Surgery, 2004