High-Performance Membrane Chromatography of Supercoiled Plasmid DNA
Authors:
- 22 July 1998
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 70 (16) , 3348-3354
Abstract
Membrane adsorbers are well established in protein chromatography. The present paper investigated for the first time the behavior of polynucleotides on these stationary phases, taking a 7.2-kb predominantly supercoiled plasmid as example. Gradient and isocratic elution was studied. In contrast to protein high-performance membrane chromatography (HPMC), isocratic elution is possible in DNA chromatography. In the case of gradient elution, much higher salt concentrations can be used in the starting buffer. Under optimized conditions, both approaches led to a splitting of the single plasmid peak into three maximums, which corresponded to the threealbeit isolatedbands in the agarose gel. Presumably the three fractions were supercoiled, nicked, and open circular plasmid DNA. Linearization of the plasmid lowered the adsorption energy, and the linearized plasmid eluted earlier than the nonlinearized one. The HPMC experiments were compared to similar ones performed using a conventional packed-bed anion-exchange column (BioScale Q2, 7 × 52 mm, 10-μm porous particles) and a novel monolithic-type anion-exchange column (UNO Q1, 7 × 35 mm). The results and characteristic differences observed in these experiments were interpreted in the light of the newly developed theory of HPMC.Keywords
This publication has 12 references indexed in Scilit:
- Effect of porous structure of macroporous polymer supports on resolution in high-performance membrane chromatography of proteinsJournal of Chromatography A, 1998
- Fast isolation of protein receptors from streptococci G by means of macroporous affinity discsJournal of Chromatography A, 1998
- Application of compact porous tubes for preparative isolation of clotting factor VIII from human plasmaJournal of Chromatography A, 1997
- Peculiarities of gradient ion-exchange high-performance liquid chromatography of proteinsJournal of Chromatography A, 1996
- Application of Compact Porous Disks for Fast Separations of Biopolymers and In-Process Control in BiotechnologyAnalytical Chemistry, 1996
- Characterization and application of strong ion-exchange membrane adsorbers as stationary phases in high-performance liquid chromatography of proteinsJournal of Chromatography A, 1993
- High-performance membrane chromatography: Highly efficient separation method for proteins in ion-exchange, hydrophobic interaction and reversed-phase modesJournal of Chromatography A, 1993
- Separation of DNA fragments by high-resolution ion-exchange chromatography on a nonporous QA columnAnalytical Biochemistry, 1990
- Purification and separation of various plasmid forms by exclusion chromatographyAnalytical Biochemistry, 1987
- Nucleic acid chromatography: Substitute solid support material for RPC-5 columnsAnalytical Biochemistry, 1986