Simple method to measure total expiratory time constant based on the passive expiratory flow-volume curve
- 1 June 1995
- journal article
- laboratory investigation
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 23 (6) , 1117-1122
Abstract
Objective In intubated, mechanically ventilated patients, inspiration is forced by externally applied positive pressure. In contrast, exhalation is passive and depends on the time constant of the total respiratory system. The expiratory time constant is thus an important determinant of mechanical ventilation. The aim of this study was to evaluate a simple method for measuring the expiratory time constant in ventilated subjects. Design Prospective study using a lung simulator and ten dogs. Setting University hospital. Subjects Commercially available lung simulator and ten greyhound dogs. Interventions Different expiratory time constants were set on the lung simulator. In the dogs, the endotracheal tube was clamped to increase airways resistance by 22.5 cm H2 O/(L/sec) and the lungs were injured with hydrochloric acid to decrease total respiratory compliance by 16 mL/cm H2 O. This procedure resulted in a wide range of expiratory time constants. Measurements and Main Results Pneumotachography was used to measure flow and volume. The ratio of exhaled volume and peak flow was calculated from these signals, corrected for the limited exhalation time yielding the "calculated expiratory time constant'' and compared with the actual expiratory time constant. The typical error was +/-0.19 sec for the lung simulator and +/-0.15 sec for the dogs. Conclusions The volume and peak flow corrected for limited exhalation time is a good estimate of the total expiratory time constant in passive subjects and may be useful for the titration of mechanical ventilation. (Crit Care Med 1995; 23:1117-1122)Keywords
This publication has 8 references indexed in Scilit:
- Maneuver-Free Determination of Compliance and Resistance in Ventilated ARDS PatientsChest, 1992
- Determinants and limits of pressure-preset ventilation: a mathematical model of pressure controlJournal of Applied Physiology, 1989
- Volume-time profile during relaxed expiration in the normal dogJournal of Applied Physiology, 1985
- A simple method for estimating complianceCritical Care Medicine, 1985
- Some suggestions for measuring predictive performanceJournal of Pharmacokinetics and Biopharmaceutics, 1981
- Digital computer calculation of human pulmonary mechanics using a least squares fit techniqueComputers and Biomedical Research, 1974
- A computers system for respiratory parametersComputers and Biomedical Research, 1969
- A new method for measurement of compliance and resistance of lungs and thoraxJournal of Applied Physiology, 1963