Low cost acetone sensors with selectivity over water vapor based on screen printed TiO2 nanoparticles
- 21 May 2013
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (15) , 3709-3713
Abstract
Noninvasive breath acetone sensors, in particular metal oxide based chemo-resistive sensors, have been actively researched recently for daily diabetes diagnosis. To find a safer alternative to the flame spray pyrolysis processing method, screen printing of commercial TiO2 paste is employed in the fabrication of metal oxide semiconductor chemo-resistors, without involving open flame, high temperature and costly instruments. The TiO2 sensing layer is found to have a desirable porous structure, with a specific surface area of 72.7 m2 g−1, when investigated using scanning electron microscopy and the Brunauer–Emmett–Teller isotherm. The new sensors are able to detect 1.5 ppm acetone, and are sensitive enough for type I diabetes diagnosis. The sensitivity survives in the presence of 90% relative humidity, offering a long targeted selectivity yet to be achieved, but essential for human breath analysis.Keywords
This publication has 29 references indexed in Scilit:
- Toward portable breath acetone analysis for diabetes detectionJournal of Breath Research, 2011
- Room-temperature-operated sensitive hybrid gas sensor based on amorphous indium gallium zinc oxide thin-film transistorsApplied Physics Letters, 2011
- Si:WO3 Sensors for Highly Selective Detection of Acetone for Easy Diagnosis of Diabetes by Breath AnalysisAnalytical Chemistry, 2010
- A Study on Breath Acetone in Diabetic Patients Using a Cavity Ringdown Breath Analyzer: Exploring Correlations of Breath Acetone With Blood Glucose and Glycohemoglobin A1CIEEE Sensors Journal, 2009
- Current Status of Methods and Techniques for Breath AnalysisCritical Reviews in Analytical Chemistry, 2007
- Measurement of Ammonia in Human Breath with a Liquid-Film Conductivity SensorAnalytical Chemistry, 2006
- Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysisMass Spectrometry Reviews, 2004
- Method for analysis of exhaled air by microwave energy desorption coupled with gas chromatography–flame ionization detection–mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1998
- GC determination of volatile components in human exhalation and in ambient atmosphere, after preconcentration on solid sorbentsChromatographia, 1997
- Respiratory water lossRespiration Physiology, 1980