Validity and Repeatability of a Novel Dynamic Visual Acuity System
Authors:
- 1 May 2017
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 94 (5) , 616-625
Abstract
Purpose: In many sports, athletes rely on visual information from the environment to perform. Some literature suggests athletes have superior visual abilities to non‐athletes, particularly on tasks representative of the visual demands of their sport, such as dynamic acuity, eye movement accuracy and speed, and peripheral vision. Other literature suggests there is no difference between athletes and non‐athletes, at least when standard clinical assessments are employed. A limitation of the literature is that almost none of the research has been conducted with standardized, validated tools. This is partly caused by a lack of readily available tools to measure tasks representative of the visual demands of sport, and available tests have typically not been validated against current clinical standards. The purpose of this study is to examine the validity and repeatability of a novel visual acuity system (moV&; V&MP Vision Suite) recently developed in the Vision & Motor Performance Lab (V&MP). moV& permits the measurement of many visual function parameters including dynamic visual acuity with predictable, random, and jittering target motion. Methods: Twenty‐five participants attended two study visits, separated by a minimum of 2 weeks. At each visit, static and dynamic visual acuity was measured using Snellen, ETDRS, and moV& charts. Static visual acuities were compared to determine the validity of moV&, and both static and dynamic visual acuities were compared between visits to determine the test–retest repeatability. Results: moV& static visual acuities are clinically similar to visual acuities measured with the ETDRS chart (moV&, −0.09 ± 0.13; ETDRS, −0.03 ± 0.11, concordance correlation coefficient 0.726). Additionally, all static, dynamic, and jitter visual acuities demonstrate good test–retest repeatability (Lin’s concordance correlation coefficient range 0.451–0.953). Conclusions: moV& provides good clinical measures of static visual acuity that are comparable to both Snellen and ETDRS measures. Dynamic visual acuity measures demonstrate good test–retest repeatability.Keywords
This publication has 25 references indexed in Scilit:
- Image Jitter Enhances Visual Performance when Spatial Resolution Is ImpairedInvestigative Ophthalmology & Visual Science, 2012
- Comparison of Dynamic Visual Acuity Between Water Polo Players and Sedentary StudentsResearch Quarterly for Exercise and Sport, 2011
- Visual Acuity and Contrast Sensitivity Testing for Sports VisionEye & Contact Lens: Science & Clinical Practice, 2011
- Effect of letter separation on computerised visual acuity measurements: comparison with the gold standard Early Treatment Diabetic Retinopathy Study (ETDRS) chartOphthalmic and Physiological Optics, 2010
- Comparison of saccadic eye movements and facility of ocular accommodation in female volleyball players and non‐playersScandinavian Journal of Medicine & Science in Sports, 2007
- Visual and psychomotor performance of elite, intermediate and novice table tennis competitorsClinical and Experimental Optometry, 1993
- Dynamic Visual Acuity and Contrast Sensitivity for Static and Flickered Gratings in a College SampleOptometry and Vision Science, 1992
- New Design Principles for Visual Acuity Letter ChartsOptometry and Vision Science, 1976
- Relationship between static and dynamic visual acuity.Journal of Experimental Psychology, 1965
- Study of Visual Acuity during the Ocular Pursuit of Moving Test Objects I Introduction*Journal of the Optical Society of America, 1958