Sandblasted/Acid-Etched vs Smooth-Surface Implants: Implant Mobility and Clinical Reaction to Experimentally Induced Peri-Implantitis in Beagle Dogs
Authors:
- Rodrigo Tadashi MartinesRMRodrigo Tadashi Martines
- Wilson Roberto SendykWSWilson Roberto Sendyk
- Alfredo GromatzkyAGAlfredo Gromatzky
- Patricia Ramos CuryPCPatricia Ramos Cury
- 1 August 2008
- journal article
- research article
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 34 (4) , 185-189
Abstract
This study uses a sandblasted/acid-etched implant vs a smooth-surface implant to compare implant mobility and clinical reactions of peri-implant tissues to experimentally induced peri-implantitis in Beagle dogs. The right and left mandibular premolars were extracted from 5 Beagle dogs, and 2 smooth-surface (SS) implants and 2 sandblasted/acid-etched (SLA) implants were placed in each animal. After 120 days, healing abutments were connected. Fifteen days later, the prosthetic abutments were connected, the hygiene regimen was suspended, and peri-implantitis was induced by the insertion of cotton ligatures into the soft tissue around the implants. At baseline and 30, 60, and 90 days later, clinical attachment level (CAL), probing depth (PD), and mobility (MO) were measured. Probing depth increased significantly in the SLA group alone when baseline PD was compared with 30-, 60-, and 90-day evaluations (P < .05). No significant differences were noted between the 2 implant groups (P > .05). The loss in CAL was significant in both groups when the baseline value was compared with 30-, 60-, and 90-day evaluations (P < .02). Comparison between the 2 implant groups revealed a greater loss in CAL in the SLA group at the 90-day evaluation period (P = .04). A significant increase in mobility was seen in both groups when baseline values and 90-day evaluations were compared (P < .04). However, no statistically significant differences were noted between the 2 implant groups (P > .05). Experimentally induced peri-implantitis results in a greater loss of CAL in SLA implants than in SS implants in dogs; however, no differences in mobility or in PD have been noted between the 2 implant groups.Keywords
This publication has 12 references indexed in Scilit:
- Effect of material characteristics and/or surface topography on biofilm developmentClinical Oral Implants Research, 2006
- Soft tissue around three different implant types after 1.5 years of functional loading without oral hygieneClinical Oral Implants Research, 2006
- Attempts to obtain re‐osseointegration following experimental peri‐implantitis in dogsClinical Oral Implants Research, 1999
- ASSESSMENT OF IMPLANT MOBILITY AT SECOND-STAGE SURGERY WITH THE PERIOTESTImplant Dentistry, 1994
- Probing depth at implants and teethJournal of Clinical Periodontology, 1993
- The reliability of pocket probing around screw‐type implantsClinical Oral Implants Research, 1991
- Criteria for success of osseointegrated endosseous implantsThe Journal of Prosthetic Dentistry, 1989
- The microbiota associated with successful or failing osseointegrated titanium implantsOral Microbiology and Immunology, 1987
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981
- The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfacesJournal of Maxillofacial Surgery, 1981