Diagnostic accuracy of a screening electronic alert tool for severe sepsis and septic shock in the emergency department
Authors:
- Sami AlsolamySASami Alsolamy
- Majid Al SalamahMSMajid Al Salamah
- Majed Al ThagafiMTMajed Al Thagafi
- Hasan M Al-DorziHAHasan M Al-Dorzi
- Abdellatif M MariniAMAbdellatif M Marini
- Nawfal AljerianNANawfal Aljerian
- Farhan Al-EneziFAFarhan Al-Enezi
- Fatimah Al-HunaidiFAFatimah Al-Hunaidi
- Ahmed M MahmoudAMAhmed M Mahmoud
- Ahmed AlamryAAAhmed Alamry
- Yaseen M ArabiYAYaseen M Arabi
Open Access
- 5 December 2014
- journal article
- research article
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 14 (1) , 105
Abstract
Early recognition of severe sepsis and septic shock is challenging. The aim of this study was to determine the diagnostic accuracy of an electronic alert system in detecting severe sepsis or septic shock among emergency department (ED) patients. An electronic sepsis alert system was developed as a part of a quality-improvement project for severe sepsis and septic shock. The system screened all adult ED patients for a combination of systemic inflammatory response syndrome and organ dysfunction criteria (hypotension, hypoxemia or lactic acidosis). This study included all patients older than 14 years who presented to the ED of a tertiary care academic medical center from Oct. 1, 2012 to Jan. 31, 2013. As a comparator, emergency medicine physicians or the critical care physician identified the patients with severe sepsis or septic shock. In the ED, vital signs were manually entered into the hospital electronic heath record every hour in the critical care area and every two hours in other areas. We also calculated the time from the alert to the intensive care unit (ICU) referral. Of the 49,838 patients who presented to the ED, 222 (0.4%) were identified to have severe sepsis or septic shock. The electronic sepsis alert had a sensitivity of 93.18% (95% CI, 88.78% - 96.00%), specificity of 98.44 (95% CI, 98.33% – 98.55%), positive predictive value of 20.98% (95% CI, 18.50% – 23.70%) and negative predictive value of 99.97% (95% CI, 99.95% – 99.98%) for severe sepsis and septic shock. The alert preceded ICU referral by a median of 4.02 hours (Q1 - Q3: 1.25–8.55). Our study shows that electronic sepsis alert tool has high sensitivity and specificity in recognizing severe sepsis and septic shock, which may improve early recognition and management.Keywords
This publication has 13 references indexed in Scilit:
- Interventions to Safeguard System Effectiveness During Periods of Emergency Department CrowdingAcademic Emergency Medicine, 2011
- Using the EMR to Perform Continuous, Automated, Real-time Surveillance to Identify Hospitalized Patients at Risk of SepsisChest, 2011
- Inpatient care for septicemia or sepsis: a challenge for patients and hospitals.2011
- Prospective Trial of Real-Time Electronic Surveillance to Expedite Early Care of Severe SepsisAnnals of Emergency Medicine, 2011
- National variation in United States sepsis mortality: a descriptive studyInternational Journal of Health Geographics, 2010
- Real‐Time Identification of Serious Infection in Geriatric Patients Using Clinical Information System SurveillanceJournal of the American Geriatrics Society, 2008
- Effect of Emergency Department Crowding on Time to Antibiotics in Patients Admitted With Community-Acquired PneumoniaAnnals of Emergency Medicine, 2007
- Overriding of Drug Safety Alerts in Computerized Physician Order EntryJournal of the American Medical Informatics Association, 2006
- Uses and abuses of screening testsThe Lancet, 2002
- Early Goal-Directed Therapy in the Treatment of Severe Sepsis and Septic ShockNew England Journal of Medicine, 2001