Deep learning‐based detection and classification of multi‐leaf collimator modeling errors in volumetric modulated radiation therapy
Authors:
Open Access
- 26 August 2023
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (12) , e14136
Abstract
Purpose: The purpose of this study was to create and evaluate deep learning‐based models to detect and classify errors of multi‐leaf collimator (MLC) modeling parameters in volumetric modulated radiation therapy (VMAT), namely the transmission factor (TF) and the dosimetric leaf gap (DLG).Methods: A total of 33 clinical VMAT plans for prostate and head‐and‐neck cancer were used, assuming a cylindrical and homogeneous phantom, and error plans were created by altering the original value of the TF and the DLG by ± 10, 20, and 30% in the treatment planning system (TPS). The Gaussian filters of and 1.0 were applied to the planar dose maps of the error‐free plan to mimic the measurement dose map, and thus dose difference maps between the error‐free and error plans were obtained. We evaluated 3 deep learning‐based models, created to perform the following detections/classifications: (1) error‐free versus TF error, (2) error‐free versus DLG error, and (3) TF versus DLG error. Models to classify the sign of the errors were also created and evaluated. A gamma analysis was performed for comparison.Results: The detection and classification of TF and DLG error were feasible for ; however, a considerable reduction of accuracy was observed for depending on the magnitude of error and treatment site. The sign of errors was detectable by the specifically trained models for and 1.0. The gamma analysis could not detect errors.Conclusions: We demonstrated that the deep learning‐based models could feasibly detect and classify TF and DLG errors in VMAT dose distributions, depending on the magnitude of the error, treatment site, and the degree of mimicked measurement doses.Keywords
This publication has 26 references indexed in Scilit:
- AAPM Medical Physics Practice Guideline 5.a.: Commissioning and QA of Treatment Planning Dose Calculations — Megavoltage Photon and Electron BeamsJournal of Applied Clinical Medical Physics, 2015
- Determining the optimal dosimetric leaf gap setting for rounded leaf‐end multileaf collimator systems by simple test fieldsJournal of Applied Clinical Medical Physics, 2015
- Determination of dosimetric leaf gap using amorphous silicon electronic portal imaging device and its influence on intensity modulated radiotherapy dose deliveryJournal of Medical Physics, 2015
- Spatial variation of dosimetric leaf gap and its impact on dose deliveryMedical Physics, 2014
- Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levelsMedical Physics, 2013
- ROC analysis in patient specific quality assuranceMedical Physics, 2013
- Dosimetry tools and techniques for IMRTMedical Physics, 2011
- Per‐beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errorsMedical Physics, 2011
- On the insensitivity of single field planar dosimetry to IMRT inaccuraciesMedical Physics, 2010
- A technique for the quantitative evaluation of dose distributionsMedical Physics, 1998