The impact of surgeons’ visual angle misperception on acetabular cup positioning accuracy: a retrospective multicenter cohort study
Open Access
- 10 September 2025
- journal article
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 112 (1) , 1101-1109
Abstract
Background: Precise acetabular cup placement in total hip arthroplasty (THA) heavily relies on surgeons’ visual judgment of angles. However, whether inherent visual angle misperception among surgeons affects surgical outcomes remains unclear. This study is the first to reveal that surgeons universally exhibit visual angle misperception, a key factor causing the cup implant positioning deviations in THA. Methods: We validated this phenomenon through three steps. Experimental validation: Five surgeons were asked completed 2D angle assessments to verify the visual angle misperception. Surgical simulation: A self-developed “Dynamic Angle-Measuring System (DAMS)” simulated cup implantation for assessing the impact of angle misperception on cup orientation. Clinical data: Retrospective analysis of 853 THA cases (683 patients) between 2015 and 2019 were collected for comparing mismatches between actual cup angles and surgeons’ target angles, and between experienced and junior surgeons. Results: All surgeons exhibited visual angle misperception in 2D and 3D angle assessments, with greater impact on anteversion than abduction angles. In in vitro simulations, discrepancies between actual and targeted anteversion angles were statistically significant (e.g., 16.8° vs. 20.0°, 22.6° vs. 25.0°; P < 0.05). These findings were corroborated in the in vivo data (e.g., 15.3° vs. 20.0°, 22.4° vs. 25.0°; P < 0.05), with an individualized fixed deviation among surgeons. Clinically, increased surgical experience only reduced the dispersion (SD value) without eliminating visual angle misperception bias. Conclusions: Our study is the first to provide that visual angle misperception is a hidden cause of cup positioning bias in THA, and experience alone cannot eliminate this bias causing by visual angle misperception, although experience reduced variability in placement. Recognizing and addressing this cognitive bias, and further targeted training to improve spatial perception, compensate inherent angle misperception bias, may lead to better patient outcomes.Keywords
This publication has 33 references indexed in Scilit:
- Effects of Method, Orientation, and Size of Angle on the Ponzo IllusionPerceptual and Motor Skills, 2000
- Why are angles misperceived?Proceedings of the National Academy of Sciences, 2000
- The effects of color on brightnessNature Neuroscience, 1999
- An Empirical Explanation of the Cornsweet EffectJournal of Neuroscience, 1999
- The influence of depicted illumination on brightnessProceedings of the National Academy of Sciences, 1998
- The distribution of oriented contours in the real worldProceedings of the National Academy of Sciences, 1998
- EBRA: A method to measure migration of acetabular componentsJournal of Biomechanics, 1995
- Dislocations after total hip-replacement arthroplasties.Journal of Bone and Joint Surgery, 1978
- Lateral Inhibition between Orientation Detectors in the Human Visual SystemNature, 1970
- Distortion of Visual Space as Inappropriate Constancy ScalingNature, 1963