Collimator angle influence on dose distribution optimization for vertebral metastases using volumetric modulated arc therapya)
Authors:
- Pietro MancosuPMPietro Mancosu
- Luca CozziLCLuca Cozzi
- Antonella FogliataAFAntonella Fogliata
- Paola LattuadaPLPaola Lattuada
- Giacomo ReggioriGRGiacomo Reggiori
- Marie Claire CantoneMCMarie Claire Cantone
- Pierina NavarriaPierina Navarria
- Marta ScorsettiMSMarta Scorsetti
- 20 July 2010
- journal article
- Published by Wiley in Medical Physics
- Vol. 37 (8) , 4133-4137
Abstract
Purpose: The cylindrical symmetry of vertebrae favors the use of volumetric modulated arc therapy in generating a dose “hole” on the center of the vertebrae limiting the dose to the spinal cord. The authors have evaluated if collimator angle is a significant parameter for dose distribution optimization in vertebral metastases.Methods: Three patients with one‐three vertebrae involved were considered. Twenty‐one differently optimized plans (nine single‐arc and 12 double‐arc plans) were performed, testing various collimator angle positions. Clinical target volume was defined as the whole vertebrae, excluding the spinal cord canal. The planning target volume (PTV) was defined as. Dose prescription was with normalization to PTV mean dose. The dose at of spinal cord was limited to 11.5Gy.Results: The best plans in terms of target coverage and spinal cord sparing were achieved by two arcs and Arc1–80° and Arc2–280° collimator angles for all the cases considered (i.e., leaf travel parallel to the spinal cord primary orientation). If one arc is used, only 80° reached the objectives.Conclusions: This study demonstrated the role of collimation rotation for the vertebrae metastasis irradiation, with the leaf travel parallel to the spinal cord primary orientation to be better than other solutions. Thus, optimal choice of collimator angle increases the optimization freedom to shape a desired dose distribution.Keywords
This publication has 13 references indexed in Scilit:
- Volumetric Modulation Arc Radiotherapy Compared With Static Gantry Intensity-Modulated Radiotherapy for Malignant Pleural Mesothelioma Tumor: A Feasibility StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Optimization of Collimator Trajectory in Volumetric Modulated Arc Therapy: Development and Evaluation for Paraspinal SBRTInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Pre-clinical evaluation of respiratory-gated delivery of volumetric modulated arc therapy with RapidArcPhysics in Medicine & Biology, 2010
- Volumetric modulated arc therapy versus conventional intensity modulated radiation therapy for stereotactic spine radiotherapy: A planning study and early clinical dataRadiotherapy and Oncology, 2010
- Re-irradiation of metastatic spinal cord compression: A feasibility study by volumetric-modulated arc radiotherapy for in-field recurrence creating a dosimetric hole on the central canalRadiotherapy and Oncology, 2010
- Critical Appraisal of Volumetric Modulated Arc Therapy in Stereotactic Body Radiation Therapy for Metastases to Abdominal Lymph NodesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Preliminary Results of Spinal Cord Compression Recurrence Evaluation (Score-1) Study Comparing Short-Course Versus Long-Course Radiotherapy for Local Control of Malignant Epidural Spinal Cord CompressionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Intensity modulation with photons for benign intracranial tumours: A planning comparison of volumetric single arc, helical arc and fixed gantry techniquesRadiotherapy and Oncology, 2008
- A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapyRadiotherapy and Oncology, 2008
- Bone metastasis consensus statementInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1992