Correction of Sampler-to-Sampler Comparisons Based on Aerosol Size Distribution
- 1 March 2007
- journal article
- research article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 4 (4) , 237-245
Abstract
This article explains a simple method for correcting a sampler-to-sampler ratio for changes in size distribution by computing a bias factor that relates the measured ratio with a ratio determined from equations that describe the collection efficiency curves of the samplers while taking size distribution into account. Laboratory trials were conducted to determine whether the resulting bias factor is independent of aerosol size distribution. During these studies, a 3-piece cassette and respirable cyclone were compared with an inhalable sampler in both a still-air chamber and a moving-air chamber operated at 0.2 m/sec and 1.0 m/sec. An ISO test dust of various size fractions was generated to produce an aerosol with mass median aerodynamic diameter ranging from 1.4 μm to 10.1 μm. An organic dust consisting of ground grain material was also applied to the still-air chamber to demonstrate differences between dust types. Results showed that the bias value was significantly different between dust types for both the cyclone/ inhalable (p=0.001) and cassette/inhalable (p=0.033) comparisons but was not different between wind conditions for either comparison. All but one comparison had insignificant slopes when comparing the bias value with median diameter, indicating that the bias value could be used to correct for size distributions in most conditions. However, bias values determined when comparing the cyclone with the inhalable sampler in the still-air condition produced a positive slope for median diameters less than 4μm(p=0.008). Further research is needed to determine why the actual cyclone/inhalable ratio decreases relative to the expected ratio as the proportion of respirable particles increases. These results suggest that, for most conditions, the size-distribution compensation can be applied to sampler-to-sampler correlations provided that the original comparison was performed with the same dust type.Keywords
This publication has 25 references indexed in Scilit:
- Performance of Personal Inhalable Aerosol Samplers in Very Slowly Moving Air When Facing the Aerosol SourceAnnals of Occupational Hygiene, 2004
- Experimental measurements of aspiration efficiency for idealized spherical aerosol samplers in calm airJournal of Aerosol Science, 2003
- Field Comparison of Inhalable and Total Dust Samplers for Assessing Airborne Dust in Swine Confinement BarnsApplied Occupational and Environmental Hygiene, 2003
- Laboratory and Field Testing of Particle Size-Selective Sampling Methods for Mineral DustsAIHA Journal, 2003
- A Field Comparison of the IOM Inhalable Aerosol Sampler and a Modified 37-mm CassetteApplied Occupational and Environmental Hygiene, 2002
- Study of fifteen respirable aerosol samplers used in occupational hygieneAnnals of Occupational Hygiene, 2001
- Calibration and Testing of Samplers with Dry, Polydisperse LatexAerosol Science and Technology, 1999
- Calibration of the SKC, Inc aluminum cyclone for operation in accordance with ISO/CEN/ACGIH respirable aerosol sampling criteria.Journal of Aerosol Science, 1998
- A technique for assessing size-selective dust samplers using the APS and polydisperse test aerosolsJournal of Aerosol Science, 1991
- A NEW PERSONAL SAMPLER FOR AIRBORNE TOTAL DUST IN WORKPLACESAnnals of Occupational Hygiene, 1986