Microwave Measurements of Moisture Content of Aggregate
Author:
- Shigeru NakayamaSNShigeru Nakayama
- 1 May 1994
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 33 (5R)
Abstract
An instantaneous method for measuring the moisture content in aggregate such as sand is developed using a microwave open-ended coaxial cavity resonator. We measure the attenuation and frequency shift of resonant peaks of the cavity resonator, which are related to the moisture content of the sand. The standard deviations in the attenuation and frequency shift are 0.30% and 0.14% in the percentage of moisture, respectively. The frequency shift measurement is better than the attenuation measurement to calculate the moisture content.Keywords
This publication has 4 references indexed in Scilit:
- Development of Microwave Caliper for Sheet MaterialsJapanese Journal of Applied Physics, 1992
- Microwave Sensor of Basis Weight and Moisture Content of Sheet Materials by Re-Entrant CavityJapanese Journal of Applied Physics, 1987
- Simultaneous Measurements of Basis Weight and Moisture Content of Sheet Materials by Microwave CavityJapanese Journal of Applied Physics, 1987
- Resonant Frequency of Open-Ended Cylindrical CavityIEEE Transactions on Microwave Theory and Techniques, 1967