Capillary electrophoretic separation of dsDNA under nonuniform electric fields
- 26 April 2003
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 376 (3) , 379-383
Abstract
Improved sensitivity for the analysis of DNA by capillary electrophoresis has been achieved, based on simultaneous increases in optical path length and injection volume. To increase the optical path length, bubble cells with diameters ranging from 150 to 450 μm have been fabricated and tested. In terms of resolution and sensitivity, a bubble cell of 300 μm diameter is appropriate when using 75-μm capillaries. To allow greater injection volumes, we performed on-line concentration of DNA in the presence of electroosmotic flow (EOF) using 2.0% poly(ethylene oxide) (PEO). With a 300-μm bubble cell, a 170-fold improvement in the sensitivity for the 89-bp fragment has been accomplished when injecting about 0.33 μL DNA. In the presence of the bubble cell, the resolution for the large fragments improves while that for the small ones (<124 base pair) decreases. The effect of bubble cells was further investigated by conducting DNA separation in the absence of EOF, showing that improvements in resolution are mainly due to increased migration differences when DNA migrated at low electric field strengths in the bubble region. We have suggested that such an effect is more profound using shorter capillaries, leading to complete separation of φX 174 RF DNA-Hae III digest in 2 min.Keywords
This publication has 32 references indexed in Scilit:
- Technical challenges in applying capillary electrophoresis-single strand conformation polymorphism for routine genetic analysisElectrophoresis, 2002
- Electrophoresis of DNA and other polyelectrolytes: Physical mechanismsReviews of Modern Physics, 2000
- Preconcentration and separation of antisense oligonucleotides by on‐column isotachophoresis and capillary electrophoresis in polymer‐filled capillariesElectrophoresis, 1998
- Signal enhancement in capillary electrophoresis by using a sleeve cell arrangement for optical detectionJournal of High Resolution Chromatography, 1997
- Analysis of Oligonucleotides by On-Column Transient Capillary Isotachophoresis and Capillary Electrophoresis in Poly(ethylene glycol)-Filled ColumnsAnalytical Chemistry, 1996
- Design of a High-Precision Fraction Collector for Capillary ElectrophoresisAnalytical Chemistry, 1995
- Characterization of Band Broadening in Capillary Electrophoresis due to Nonuniform Capillary GeometriesAnalytical Chemistry, 1994
- Optical improvements of a Z-shaped cell for high-sensitivity UV absorbance detection in capillary electrophoresisAnalytical Chemistry, 1993
- A simple means to increase absorbance detection sensitivity in capillary zone electrophoresisAnalytica Chimica Acta, 1993
- Nanoliter-scale multireflection cell for absorption detection in capillary electrophoresisAnalytical Chemistry, 1991