Formaldehyde, aliphatic aldehydes (C 2 ‐C 11 ), furfural, and benzaldehyde in the residential indoor air of children and adolescents during the German Environmental Survey 2014–2017 (GerES V)
Open Access
- 2 September 2021
- journal article
- research article
- Published by Wiley in Indoor Air
- Vol. 32 (1) , e12927
Abstract
Indoor air concentrations of formaldehyde, furfural, benzaldehyde, and 11 aliphatic aldehydes (C2-C11) were measured in residences of 639 participants in the German Environmental Survey for Children and Adolescents 2014–2017 (GerES V). Sampling was conducted using passive samplers over periods of approximately seven days for each participant. The most abundant compounds were formaldehyde and hexanal with median concentrations of 24.9 µg m−3 and 10.9 µg m−3, respectively. Formaldehyde concentrations exceeded the Guide Value I recommended by the German Committee on Indoor Guide Values (Ausschuss für Innenraumrichtwerte - AIR) (0.10 mg m−3) for 0.3% of the participating residences. The sum of aliphatic n-aldehydes between C4 (butanal) and C11 (undecanal) exceeded their Guide Value (0.10 mg m−3) for 2.0% of the residences. The geometric mean concentrations of most aldehydes were lower than in the earlier GerES IV (2003–2006) study. Formaldehyde and hexanal concentrations, however, were comparable in both studies and showed no significant difference. Indoor aldehyde concentrations did not exhibit significant correlations with factors collected in questionnaires, such as the age of the participants, their socio-economic status, the location of the residence (former East/West Germany), migration background, tobacco exposure, and the type of furniture used. The validity of the passive sampler measurements was verified against active sampling techniques in a test chamber experiment.Keywords
This publication has 50 references indexed in Scilit:
- Recent trend in risk assessment of formaldehyde exposures from indoor airArchives of Toxicology, 2012
- Environmental surveys, specimen bank and health related environmental monitoring in GermanyInternational Journal of Hygiene and Environmental Health, 2012
- Hazard assessment of chemical air contaminants measured in residencesIndoor Air, 2011
- Formaldehyde in the Indoor EnvironmentChemical Reviews, 2010
- The challenge of comprehensively mapping children's health in a nation-wide health survey: Design of the German KiGGS-StudyBMC Public Health, 2008
- Impact of reaction products from building materials and furnishings on indoor air quality—A review of recent advances in indoor chemistryAtmospheric Environment, 2007
- Estimating contributions of indoor and outdoor sources to indoor carbonyl concentrations in three urban areas of the United StatesAtmospheric Environment, 2006
- Validation of a diffusive sampler for the determination of acetaldehyde in airThe Analyst, 1996
- High‐performance liquid‐chromatographic determination of fgrivialdehyde in air in the ppb to ppm range using diffusive sampling and hydrazone formationEnvironmental Technology Letters, 1988
- Identification of the most intense volatile flavour compounds formed during autoxidation of linoleic acidEuropean Food Research and Technology, 1987