The Accuracy of a Continuous Blood Glucose Monitor During Surgery
Authors:
- Koichi YamashitaKYKoichi Yamashita
- Takehiro OkabayashiTOTakehiro Okabayashi
- Takeshi YokoyamaTYTakeshi Yokoyama
- Tomoaki YatabeTYTomoaki Yatabe
- Hiromichi MaedaHMHiromichi Maeda
- Masanobu ManabeMMMasanobu Manabe
- Kazuhiro HanazakiKHKazuhiro Hanazaki
- 1 January 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 106 (1) , 160-163
Abstract
Protocols for tight control of blood glucose can be difficult to achieve in the surgical setting, especially when relying upon intermittent blood glucose testing. A continuous blood glucose monitoring system can facilitate blood glucose management. In the present study, we compared blood glucose measured continuously (STG-22, Nikkiso, Tokyo, Japan), during surgery with coincident measurements obtained intermittently using a conventional laboratory glucometer (ABL 800FLEX (Radiometer Medical Aps, [symbol: see text], Denmark). The goal of the study was to determine the reliability and accuracy of the continuous method during surgery. Twenty-nine patients scheduled for routine surgery with general anesthesia were enrolled in this study. After anesthetic induction, a 20G IV catheter was inserted in a peripheral forearm vein and connected to the continuous blood glucose monitor. A radial arterial catheter was also inserted from which samples for blood glucose estimation were obtained by an anesthesiologist, following an established protocol of discarding 3 mL of blood before the actual blood sampling. Blood glucose was measured by ABL 800FLEX immediately after sampling. One hundred points of paired blood glucose values were obtained, which were compared using Bland and Altman analysis. Bias and upper and lower limits of agreement were -2.6, 23, and -28, respectively. The percentage error of the lower/upper limits of agreement was 21% and 18%, respectively. The blood glucose measurements obtained continuously agreed with the coincident intermittent measurements within 21%. The STG-22 may still be useful for following changes continuously and reducing the frequency of intermittent measurement, but the need for testing samples with a reliable device is not eliminated.Keywords
This publication has 11 references indexed in Scilit:
- Intensive insulin therapy to non-cardiac ICU patientsEuropean Journal of Anaesthesiology, 2006
- Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical careComputer Methods and Programs in Biomedicine, 2006
- Continuous glucose monitoring and closed‐loop systemsDiabetic Medicine, 2005
- Pancreatic Polypeptide Administration Reduces Insulin Requirements of Artificial Pancreas in Pancreatectomized DogsArtificial Organs, 2005
- Effect of an Intensive Glucose Management Protocol on the Mortality of Critically Ill Adult PatientsMayo Clinic Proceedings, 2004
- Glucose Control and Mortality in Critically Ill PatientsJAMA, 2003
- Intensive Insulin Therapy in Critically Ill PatientsNew England Journal of Medicine, 2001
- Calculating correlation coefficients with repeated observations: Part 2—correlation between subjectsBMJ, 1995
- Impaired Feedback Inhibition of Insulin Secretion by Hyperinsulinemia in Patients with Insulinoma.Endocrine Journal, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986