Magnetic resonance imaging interactions with a sacral neuromodulation system
Open Access
- 6 September 2021
- journal article
- research article
- Published by Wiley in Neurourology and Urodynamics
- Vol. 40 (8) , 1862-1868
Abstract
Aims: Sacral neuromodulation (SNM) has successfully treated patients with functional urinary and/or bowel disorders for more than two decades. Historically, patients with the InterStim system (Medtronic) were contraindicated for Magnetic Resonance Imaging (MRI) scans. In 2012, Medtronic obtained Food and Drug Administration (FDA) approval for allowing 1.5 Tesla (T) MRI head scans. In September 2019, the Axonics System (Axonics) received FDA approval for 1.5 T full‐body MR Conditional labeling and then 3 T full‐body MR Conditional labeling in July 2020. In August 2020, Medtronic received 1.5 and 3 T full‐body MR Conditional labeling from the FDA for their new SNM systems (InterStim II and Micro devices with SureScanTM leads). With the advancements in MRI technology and availability of full‐body MRI eligible SNM systems, it is important for physicians to better understand MRI safety for these systems.Methods: This paper explains the fundamentals of MRI physics, its interactions with active implantable medical devices (AIMDs), the subsequent potential safety hazards with emphasis on radio frequency (RF)‐related safety, and the risks associated with “Off‐label” scans, including abandoned and broken leads.Results: MRI guidelines provided by the AIMD device manufacturer should be followed to ensure MRI scan safety and avoid any unnecessary risk to patients.Conclusions: MRI guidelines provided by the device manufacturer are the best resource for guidance for performing safe MRI scanning. Specific conditions should be fully understood and generalizations on MRI safety claims based on partial analysis or case studies should be avoided.Keywords
This publication has 27 references indexed in Scilit:
- Safety and Outcomes of Magnetic Resonance Imaging in Patients with Abandoned Pacemaker and Defibrillator LeadsPacing and Clinical Electrophysiology, 2014
- Impact of capped and uncapped abandoned leads on the heating of an MR‐conditional pacemaker implantMagnetic Resonance in Medicine, 2014
- Patterns of Hardware Related Electrode Failures in Sacral Nerve Stimulation DevicesJournal of Urology, 2013
- Magnetic resonance imaging following interstim®: An institutional experience with imaging safety and patient satisfactionNeurourology and Urodynamics, 2011
- First MRI-Safe Pacemaker Receives Conditional Approval From FDAJAMA, 2011
- Pacemaker lead tip heating in abandoned and pacemaker‐attached leads at 1.5 tesla MRIJournal of Magnetic Resonance Imaging, 2011
- Safety of MRI at 1.5Tesla in Patients with Implanted Sacral Nerve NeurostimulatorEuropean Urology, 2006
- Neurostimulation System Used for Deep Brain Stimulation (DBS)Investigative Radiology, 2004
- MRT bei Patienten mit Herzschrittmachern: In-vitro- und In-vivo-Evaluierung bei 0,5 TeslaRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1998
- Safe Performance of Magnetic Resonance Imaging on Five Patients with Permanent Cardiac PacemakersPacing and Clinical Electrophysiology, 1996