The density difference between tissue and neural probes is a key factor for glial scarring
Open Access
- 15 October 2013
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 3 (1) , srep02942
Abstract
A key to successful chronic neural interfacing is to achieve minimal glial scarring surrounding the implants, as the astrocytes and microglia may functionally insulate the interface. A possible explanation for the development of these reactions is mechanical forces arising between the implants and the brain. Here, we show that the difference between the density of neural probes and that of the tissue, and the resulting inertial forces, are key factors for the development of the glial scar. Two probes of similar size, shape, surface structure and elastic modulus but differing greatly in density were implanted into the rat brain. After six weeks, significantly lower astrocytic and microglial reactions were found surrounding the low-density probes, approaching no reaction at all. This provides a major key to design fully biocompatible neural interfaces and a new platform for in vivo assays of tissue reactions to probes with differing materials, surface structures, and shapes.Keywords
This publication has 33 references indexed in Scilit:
- Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfacesNature Materials, 2012
- Multiple Implants Do Not Aggravate the Tissue Reaction in Rat BrainPLOS ONE, 2012
- Comprehensive Analysis of Tissue Preservation and Recording Quality from Chronic Multielectrode ImplantsPLOS ONE, 2011
- Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNSPLOS ONE, 2011
- Biocompatibility of intracortical microelectrodes: current status and future prospectsFrontiers in Neuroengineering, 2010
- Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical OpportunitiesJournal of Neuroscience, 2008
- Complex impedance spectroscopy for monitoring tissue responses to inserted neural implantsJournal of Neural Engineering, 2007
- The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skullJournal of Biomedical Materials Research Part A, 2007
- Brain micromotion around implants in the rodent somatosensory cortexJournal of Neural Engineering, 2006
- Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arraysExperimental Neurology, 2005