A kinematic model representing the versatility of the human hand is needed to evaluate biomechanical function and predict injury risk in the workplace. We improved upon an existing optoelectronic-based kinematic hand model with grouped metacarpals by defining segmented metacarpals and adding the trapeziometacarpal joint of the thumb. Eight participants performed three static postures (neutral pose, cylinder grip, cap grip) to evaluate kinematic performance of three different models, with one, two, and four metacarpal segment(s). Mean distal transverse metacarpal arch angles in the four-segment metacarpal model were between 22.0° ± 3.3° (neutral pose) and 32.1° ± 3.7° (cap grip). Representation of the metacarpals greatly influenced metacarpophalangeal joint rotations. Both the two- and four-segment metacarpal models displayed significantly lower metacarpophalangeal joint ‘supination’ angles (than the one-segment model) for the fourth and fifth fingers. However, the largest reductions were for the four- versus one-segment models, with mean differences ranging from 9.3° (neutral pose) to 17.0° (cap grip) for the fourth finger and 16.3° (neutral pose) to 33.0° (cylinder grip) for the fifth finger. MCP joint abduction/adduction angles of the fourth and fifth fingers also decreased with segmentation of the metacarpals, although the lowest magnitudes generally occurred in the four-segment model. Overall, the four-segment metacarpal model produced the lowest accessory rotations in non-dominant axes, and best matched previous radiological studies that found MCP joint pronation/supination angles were typically less than 10°. The four-segment metacarpal model, with improved anatomic fidelity, will better serve future studies of detailed actions of the hand in clinical or work applications.Keywords
This publication has 21 references indexed in Scilit:
- A method for defining carpometacarpal joint kinematics from three-dimensional rotations of the metacarpal bones captured in vivo using computed tomographyJournal of Biomechanics, 2013
- A technique for motion capture of the finger using functional joint centres and the effect of calibration range of motion on its accuracyProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2012
- Modeling of the muscle/tendon excursions and moment arms in the thumb using the commercial software anybodyJournal of Biomechanics, 2009
- Anatomy and Pathomechanics of the ThumbHand Clinics, 2008
- Arches of the hand in reach to graspJournal of Biomechanics, 2008
- Analysis of skin movement with respect to flexional bone motion using MR images of a handJournal of Biomechanics, 2006
- Experimental protocol for the kinematic analysis of the hand: Definition and repeatabilityGait & Posture, 2006
- Three-dimensional rotations of human three-joint fingers: an optoelectronic measurement. Preliminary resultsSurgical and Radiologic Anatomy, 2004
- Measurement of three-joint-finger motions: reality or fancy? A three-dimensional anatomical approachSurgical and Radiologic Anatomy, 2003
- Three-dimensional kinematic analysis of the second through fifth carpometacarpal jointsThe Journal of Hand Surgery, 2001