Experience of 500 cases of neurophysiological monitoring in carotid endarterectomy
- 22 June 2007
- journal article
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 149 (7) , 681-689
Abstract
Background. Experience with Intraoperative monitoring using neurophysiological and haemodynamic indices in 500 operations for carotid endarterectomy is reported. Methods. Transcranial Doppler technique (TCD), electroencephalogram (EEG) and bilateral median somatosensory evoked potentials (SEP) were performed. Latency and amplitude of SEP, spectral analysis of EEG signal and blood flow velocity in the medial cerebral artery (MCA) were continuously measured. Findings. After two consecutive drops of N20/P25 complex of more than 50%, a warning was given, and when the decrease continued, an the alarm raised. Abnormal EEG changes, if any, appeared after a significant decrease in the N20/P25 amplitude. A mean blood flow velocity drop below 40% of the reference value after cross clamping was rated as a significant warning event. A warning as a result of a decrease in N20/P25 amplitude occurred in 80 operations (16.0%), after an spectral edge frequency decrease in 2 cases (0.4%) and after a Vmean decrease in 21 cases (4.2%). False negative results were experienced in 2 patients (0.4%). A shunt was inserted in 2.8% of the operations. The overall mortality/morbidity rate was 2.4%. Conclusion. A decrease of more than 50% in the amplitude of the thalamocortical somatosensory evoked potential complex N20/P25 proved to be the most reliable warning of danger of ischaemia during carotid endarterectomy.Keywords
This publication has 39 references indexed in Scilit:
- Comparison between degree of carotid stenosis observed at angiography and in histological examinationActa Neurochirurgica, 2004
- Extracranial Carotid Artery StenosisStroke, 2003
- Carotid artery stenting: analysis of data for 105 patients at high risk1 1Competition of interest: none.Journal of Vascular Surgery, 2003
- Silent Cerebral Ischemia Detected by Diffusion-Weighted MRI After Carotid EndarterectomyStroke, 2000
- Intraoperative Monitoring of the Somatosensory Evoked Potentials and Cerebral Blood Flow During Aneurysm SurgeryNeurologia medico-chirurgica, 1991
- Effects of temporary arterial occlusion on somatosensory evoked responses in aneurysm surgerySurgical Neurology, 1987
- Evoked potentials in cerebral ischemia.Stroke, 1986
- The accuracy of carotid back pressure as an index for shunt requirements. A reappraisal.Stroke, 1982
- Thresholds in cerebral ischemia - the ischemic penumbra.Stroke, 1981
- Correlation of Continuous Electroencephalograms With Cerebral Blood Flow Measurements During Carotid EndarterectomyStroke, 1973