Automated BET, Blood Pressure, and IVH
Authors:
- 9 October 1988
- journal article
- Published by Wiley in Pediatrics International
- Vol. 30 (5) , 588-593
Abstract
An automated apparatus for blood exchange transfusion (BET) has been devised with a two‐site technique for peripheral artery and vein, utilizing an Atom infusion pump. With this apparatus, we have successfully performed exchange transfusions 189 times in 110 infants with birth weights ranging from 530 g to 4,000 g within the past four years.Evaluating the influence of this method on the circulatory system, the variation in blood pressure (BP) during exchange transfusions was consecutively measured 29 times in 16 infants (14 cases by indirect method and two cases by direct method). The BP was very stable, without any significant change in the mean and the coefficient variation (CV) before, during and after the transfusion (Systolic BP: 59.3±11.9, 60.1±11.9, and 60.3±12.1 mmHg; p: n. s., CV: 7.8±4.1, 8.1±3.8, and 7.7±4.1%; p: n. s., respectively).Further, in evaluating the influence of the method on the occurrence of intraventricular hemorrhage (IVH), brain ultrasonography was performed in 20 extremely premature infants of less than 1,500 g in birth weight prior to and following the exchange transfusion. There was no significant occurrence or exacerbation of IVH. by the method itself (IVH Grade 0: 15 cases, Grade 1: 4 cases, Grade 2: 1 case).We believe that this automated method may be more stable as it relates to variation of systemic BP and that the occurrence of IVH especially in extremely premature infants may be less likely with the automated method than with the use of Diamond's method, since it is isovolemic in procedure.Keywords
This publication has 15 references indexed in Scilit:
- Automated apparatus for exchange transfusionThe Journal of Pediatrics, 1984
- Fluctuating Cerebral Blood-Flow Velocity in Respiratory-Distress SyndromeNew England Journal of Medicine, 1983
- Automated method for exchange transfusion: A new modificationThe Journal of Pediatrics, 1983
- Changes in intracranial pressure during exchange transfusionThe Journal of Pediatrics, 1979
- Impaired autoregulation of cerebral blood flow in the distressed newborn infantThe Journal of Pediatrics, 1979
- Incidence and evolution of subependymal and intraventricular hemorrhage: A study of infants with birth weights less than 1,500 gmThe Journal of Pediatrics, 1978
- Alterations in blood pressure during exchange transfusion.Archives of Disease in Childhood, 1977
- Colonic Perforation after Exchange TransfusionBMJ, 1968
- Transfusions in newborn infants through abdominalwall segment of umbilical veinThe Journal of Pediatrics, 1948
- A new technique for replacement transfusion in the treatment of hemolytic disease of the newborn infantThe Journal of Pediatrics, 1948