Capacitance probes (CP) based on responses to electromagnetic properties in soil are widely used for monitoring soil volumetric water content (θ v ), but proper calibration is necessary to obtain reliable results. The objectives of this study were to: (i) compare errors in evaluating θ v when using soil‐specific equations as opposed to the manufacturer's default equation; (ii) compare the CP calibration equations obtained in the laboratory and in the field; and (iii) evaluate the accuracy of CP under field conditions using soil‐specific equations as opposed to the manufacturer's default equation. Laboratory and field calibrations were conducted by fitting statistical relationships between readings from CP and θ v measured from soil cores. The accuracies of the obtained calibration equations were evaluated under field conditions during two irrigation cycles. In both calibration studies, the manufacturer's default equation consistently overcalculated θ v (RMSE > 0.044 m 3 m −3 ), whereas custom CP calibration equations provided accurate θ v determinations (RMSE < 0.028 m 3 m −3 ). Even when θ v was overestimated, the manufacturer's default equation was able to reproduce θ v dynamics during irrigation. Therefore, if users are interested in relative differences in θ v , they may use the manufacturer's default equation. If absolute values are needed, however, soil‐specific calibration is required. The accuracy of CP in monitoring θ v under field conditions was slightly better using the laboratory calibration equation (RMSE = 0.019 m 3 m −3 ) rather than the field calibration equation (RMSE = 0.023 m 3 m −3 ). The use of a laboratory calibration is recommended given that it is easily reproducible, facilitates work planning, and minimizes uncertainties.Keywords
Funding Information
- Ministerio de Educación de la Nación (AGL2005-08020-C05-04, AGL2008-00163/AGR)
This publication has 21 references indexed in Scilit:
- REAL‐TIME SOIL WATER MONITORING FOR OPTIMUM WATER MANAGEMENT1Jawra Journal of the American Water Resources Association, 2006
- Drainage and nitrate leaching in a crop rotation under different N-fertilizer strategies: application of capacitance probesPlant and Soil, 2006
- Soil Profile Water Content Determination: Sensor Accuracy, Axial Response, Calibration, Temperature Dependence, and PrecisionVadose Zone Journal, 2006
- Advances in Crop Water Management Using Capacitive Water Sensors2006
- Dual Field Calibration of Capacitance and Neutron Soil Water Sensors in a Shrinking–Swelling Clay SoilVadose Zone Journal, 2004
- Soil Material, Temperature, and Salinity Effects on Calibration of Multisensor Capacitance ProbesSoil Science Society of America Journal, 2000
- Evaluation of capacitance probes for optimal irrigation of citrus through soil moisture monitoring in an entisol profileIrrigation Science, 2000
- Soil moisture monitoring at the field scale using automatic capacitance probesEuropean Journal of Soil Science, 1998
- The dielectric behaviour of clay soils and its application to time domain reflectometrySoil Research, 1996
- Mesure de l'humidité des sols par une méthode capacitive : analyse des facteurs influençant la mesureAgronomy for Sustainable Development, 1993